ALARMS THAT CAN APPEAR ON THE
DISPLAY:

OVERTEMPERATURE: OVERTEMP

-

Heater is sttoped and  the following screen appears:

-

To remove the screen indications press (7), let cold
the liquid and  press again (7) to start.

Action to solve:
1) Stop the equipment pressing the key (7).
2) Reset the safety thermostat placed at the rear

part of the machine. Review the temperature
adjustement of the thermostat.

3) Start pressing (7).

UNDERTEMPERATURE:UNDERTEMP 

(See pag 7).

LEVEL:
-

The following screen appears:

-

To remove the screen indications press (7), let cold
the fluid and  press again (7) to start.

PROBE:

1- The screen shows:

ALARMAS QUE PUEDEN APARECER EN
PANTALLA:

SOBRETEMPERATURA:OVERTEMP

- Cuando se activa la alarma se corta la calefacción

y aparece en pantalla lo siguiente:

- Para desactivar la alarma accionar el pulsador (7),

dejar enfriar el líquido y volver a accionar el pulsador
(7) para poner en marcha.

Acción correctora:

1)

Parar el equipo mediante el pulsador (7).

2)

Resetear el termostato de seguridad fijado en

la parte posterior del equipo.

Revisar ajuste temperatura del termostato.

3)

Poner en marcha mediante el pulsador (7).

BAJA TEMPERATURA:UNDERTEMP

- Cuando se activa la alarma aparece en pantalla lo

siguiente:

- Para desactivar la alarma accionar el pulsador (7),

dejar temperar el líquido y volver a accionar el pul-
sador (7) para poner en marcha.

SONDA:

1-

 

Aparece en pantalla:

UNDERTEMP

STATUS

PV

ALARM

Donde PV es la temperatura actual leída.

Where PV is the present temperature read.

UNDERTEMP

STATUS

PV

ALARM

Donde PV es la temperatura actual leída.

Where PV is the present temperature read.

RTD FAIL

STATUS

INT OPEN

ALARM

Summary of Contents for RONER/D

Page 1: ...es sin previo aviso Pag 1 J P SELECTA s a Ctra NII Km 585 1 Abrera 08630 Barcelona Espa a Tel 34 937 700 877 Fax 34 937 702 362 e mail selecta jpselecta es website www jpselecta es TERMOSTATO DE INMER...

Page 2: ...des prender vapores o formar mezclas explosivas o inflamables NDICE CONTENTS P G PAGE INFORMACI N GENERAL GENERAL INFORMATION 2 NDICE CONTENTS 2 LISTADE EMBALAJE PACKING LISTS 3 ESPECIFICACI N T CNIC...

Page 3: ...mperatura m xima y m nima de trabajo seleccionables Correcci n de lectura seleccionable Conexion para sonda exterior Lectura en grados Farenheit o Celsius TECHNICAL FEATURES Voltage supply 115 230V 50...

Page 4: ...zul Neutro Cable marron Fase Cable Amarillo Verde Tierra When using the drainage tap placed at the front part of the tank take care that it can be at a high temperature Leave it to cool or use some ki...

Page 5: ...t shows the desired temperature on the display DEFAULT PARAMETERS Alarma sobretemperatura Overtemperature alarm OVERTEMP OFF Alarma baja temperatura Undertemperature alarm UNDERTEMP OFF L mite inferio...

Page 6: ...at STATUS STOP Press 3 one time on the display appears OVERTEMP by pressing 5 or 6 the overtemperature degrees are selected The alarm is activated when the read temperature PV ex ceeds the overtempera...

Page 7: ...sta que aparezca la pantalla inicial MAXIMUM WORKING TEMPERATURE Press 4 until the display shows LOWER LIM Press 3 until the display shows UPPER LIM By pressing 5 and 6 select the desired value Press...

Page 8: ...ROBE 1 The screen shows ALARMAS QUE PUEDEN APARECER EN PANTALLA SOBRETEMPERATURA OVERTEMP Cuando se activa la alarma se corta la calefacci n y aparece en pantalla lo siguiente Para desactivar la alarm...

Page 9: ...ocircuitada Efecto Desactiva la calefacci n Acci n correctora 1 Parar el equipo mediante el pulsador 7 2 Comprobar que est correctamente conectada la sonda exterior 3 Poner en marcha mediante el pulsa...

Page 10: ...e is placed at the rear part of the apparatus head and the contacts are disposed according to figure 1 To read through this probe select EX SENSOR according to the following configuration diagram RECA...

Page 11: ...tas a modificaciones sin previo aviso Pag 11 J P SELECTA s a Ctra NII Km 585 1 Abrera 08630 Barcelona Espa a Tel 34 937 700 877 Fax 34 937 702 362 e mail selecta jpselecta es website www jpselecta es...

Page 12: ...ect the apparatus from the mains If tapwater is used there will be calcareous depositions on the bottom of the tank and on the heating element Use of the heating element must be avoided when covered w...

Reviews: