Now  that  your  electrodes  and  battery  are  connected,  insert 

morph lock

 

through the proximal end of the prosthesis (i.e. end opposite of the lamination 

collar).

Ensure  that  the  flat  side  of  the 

antenna is flush against the 
proximal side of the lamination 

collar. Antenna cable should extend 

into the prosthesis. 

Use  a  small  amount  of  adhesive 
(i.e. glue) to secure the antenna to 
the lamination collar.

Lamination 

Collar

morph lock

Antenna

Antenna Cable

Antenna

INSTALLATION WITHOUT A WRIST

WARNING: Do not place 

morph lock

 in a carbon fiber prosthesis. 

morph lock

 cannot detect tags through carbon fiber.

Place glue here

Summary of Contents for morph lock

Page 1: ...1 morph lock InstallationandSetupGuide for the Prosthetist ...

Page 2: ...document provides information for the prosthetist who will be installing morph lock FCC ID O7Q MORPH2 IC 21990 MORPH2 Contains FCC ID XDULE40 D2 Contains IC 8456A LE4D2 Infinite Biomedical Technologies LLC 8 Market Place Suite 500 Baltimore MD 21202 443 451 7175 www i biomed com Mdi Europa GmbH Langenhagener Str 71 30855 Langenhagen Germany ...

Page 3: ...f morph lock should be performed exclusively by a licensed prosthetist or technician morph lock is intended to be operated by a prosthesis user following installation and setup Any unauthorized handling or installation of morph lock could void its warranty Any questions We re happy to help Call us or send us an email 443 451 7175 support i biomed com This symbol is used throughout the guide to ind...

Page 4: ...Before you Begin 8 Batteries and Electrodes 9 Installation without a Wrist 10 Installation with a Wrist 13 5 Test morph lock 17 6 Using Tags 18 7 Troubleshooting 21 8 Maintaining morph lock 23 Preventative Inspection 23 Maintenance 23 Disposal 23 Repairs Returns and Warranty 23 9 Safety and Warnings 24 ...

Page 5: ...pproaching a tag again resumes EMG input and unlocks the hand morph lock does not remove any functionality from the prosthetic hand Users can continue to use traditional operation to switch functions as needed without the use of tags morph lock is compatible with most hands and wrists that accept standard analog electrodes with three port kidney style connectors Examples include the Motion Control...

Page 6: ...s on the lamination collar of the prosthesis The antenna is permanently attached to the controller box do not try to disconnect the antenna from the controller box Tags are small objects that store the lock command When morph lock comes close to a tag morph lock wirelessly reads the tag and interrupts the EMG signal to the hand For more details on the tags and how to incorporate them into the user...

Page 7: ...torage transport 15 93 Atmospheric pressure range 860 hPa 1060 hPa Input voltage 7 4V Maximum Output Current 3A Compatible battery FlexCell Recommended battery capacity Depends on terminal device Contact us for recommendations Expected service life 3 years Compatible electrode Standard analog electrodes with three port kidney style connectors Tag range 1 8cm 0 4 3 1 3 ...

Page 8: ...G electrodes with three port kidney style connectors Terminal device Coaxial plug Lamination collar parts Optional Ottobock wrist 10S17 with MyoRotronic 13E205 ProWrist 5010056 If using ProWrist also need Motion Control Battery Adapter Cable 3010461 BEFORE YOU BEGIN WARNING Do not place morph lock in a carbon fiber prosthesis morph lock cannot detect tags through carbon fiber ...

Page 9: ... does not matter which electrode is plugged into which input cable The signals can be later switched in the hand software Make sure the cables are plugged in all the way Electrode Cables morph lock Controller Box WARNING Turn the battery OFF before plugging in any cables Do not attempt to connect the battery or electrodes in a way that is not specified This could cause permanent damage to morph lo...

Page 10: ...lush against the proximal side of the lamination collar Antenna cable should extend into the prosthesis Use a small amount of adhesive i e glue to secure the antenna to the lamination collar Lamination Collar morph lock Antenna Antenna Cable Antenna INSTALLATIONWITHOUTAWRIST WARNING Do not place morph lock in a carbon fiber prosthesis morph lock cannot detect tags through carbon fiber Place glue h...

Page 11: ...e in the lamination collar WARNING Ensure the battery is OFF before plugging in any cables Do not attempt to connect the morph lock output cables in a way that is not specified This could cause permanent damage to the hand and morph lock On the coaxial plug Plug the morph lock red power cable to the pins labeled 1 Plug the morph lock orange cables to the pins labeled 2 Make sure the cables are plu...

Page 12: ...12 Insert the coupling piece into the laminiation collar and secure it with the large o ring Insert the coaxial plug into the lamination collar coupling piece and seal it in place using the small o ring ...

Page 13: ...a Cable Antenna Place glue here Ottobock Wrist 10S17 with MyoRotronic 13E205 First remove the wrist from the prosthesis Ensure that the flat side of the antenna is flush against the proximal side of the lamination collar Antenna cable should extend into the prosthesis Use a small amount of adhesive i e glue to secure the antenna to the lamination collar Pull the morph lock output wires through the...

Page 14: ... lock On the MyoRotronic 13E205 Plug the morph lock red power cable to the pins labeled with a battery symbol Plug the morph lock orange cables to the pins labeled 1 and 2 Make sure the cables are plugged in all the way NOTE The wrist itself may contain cables that need to be plugged into specific pins for example the pins labeled M For any wrist cables that need to be connected please consult the...

Page 15: ... remove the wrist from the prosthesis As in the case of the Ottobock Wrist 10S17 with MyoRotronic 13E205 ensure that the flat side of the antenna is flush against the proximal side of the lamination collar Antenna cable should extend into the prosthesis Use a small amount of adhesive i e glue to secure the antenna to the lamination collar Pull the morph lock output wires through the hole in the la...

Page 16: ...ist should slide through the morph lock antenna Secure the ProWrist to the lamination collar with the screws Motion Control Battery Adapter Cable 3010461 Keep disconnected ProWrist 9 pin Connector for Input Device ProWrist 4 pin Power Cable ProWrist morph lock red power cable morph lock blue cable WARNING Ensure the battery is OFF before plugging in any cables Do not attempt to connect the morph l...

Page 17: ...rsed i e close electrode opens the hand connect to the hand s software and switch the EMG signals Approach a tag to the wrist area of the prosthesis where the morph lock antenna resides morph lock will vibrate twice to indicate that it has detected the tag and locked the hand Tap the electrodes to confirm that the hand does not respond to EMG Approach another tag and morph lock will vibrate once t...

Page 18: ...Several tags are included with your morph lock shipment The tags are already programmed and ready to use TAG SIZES You will notice that your tags come in different sizes Larger tags have a longer range 1 3 than smaller tags 1 TAG VIBRATION PATTERNS Everytime it detects a tag morph lock vibrates to notify the user that it has read the tag morph lock creates different vibration patterns depending on...

Page 19: ...ter grabbing a plate from the cabinet Tag near the refrigerator to lock prosthesis after grabbing beverage from the refrigerator door Tag on the wall near the exit to securely carry a dish out to the dining room TAG PLACEMENT Closet Tag on the closet wall to lock the hand in a closed position while sliding the prosthetic arm through a coat sleeve Office Tag at the edge of the desk to lock the hand...

Page 20: ...smaller tags to reduce the risk of overlap Only use tags sold by IBT There are several variations of tags on the market morph lock only works with a specific type of tag provided by IBT Contact IBT if you need additional tags Sticker tags Some of your tags may be stickers Advise your user not to wet these tags Also advise your user to avoid sticking and unsticking the tags multiple times as this m...

Page 21: ...charged tap the electrodes to see if the hand moves If it does morph lock and the hand are receiving power It is possible that morph lock is installed in a way that dampens the vibration Please note that the vibration may be easier to detect while wearing the prosthesis Try placing your finger in the inner socket to feel the vibration there If the hand does not move morph lock and the hand are not...

Page 22: ...PANELECTRODE First check that the battery is on and charged Press the button on FlexCell to ensure that there is charge remaining on the battery If discharged connect the charger and test again after charging If powered off turn the battery on and approach the tag again If the battery is charged attempt tapping the other electrode to determine if this creates a response If it does the electrode th...

Page 23: ...t connectors Follow the instructions in Section 4 to plug in the new electrode or battery For any abnormal issues discontinue use and contact IBT for support DISPOSAL REPAIRS RETURNS AND WARRANTY Please contact IBT at service i biomed com regarding repairs and returns morph lock comes with a 1 year manufacturer s defect warranty Details of the warranty are enclosed separately morph lock should not...

Page 24: ...is may cause morph lock to be permanently damaged If the user will be wearing their prosthesis in wet environments ensure that morph lock is sufficiently protected from the external environment Battery use warning morph lock must be powered by a FlexCell battery system from IBT We have conducted safety testing to confirm compatibility between morph lock and FlexCell batteries Modification warning ...

Page 25: ...rence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connec...

Page 26: ...26 notes ...

Page 27: ...27 notes ...

Page 28: ...28 Z 0 0 0 0 0 7 3 r e v 1 J u l 2 0 1 8 ...