6
6.2.3. Operation
•
Place the workpiece to be cleaned on the support rack.
•
Press the foot switch to turn the device on.
•
Clean the workpiece with the brush.
•
Release the foot switch to turn the pump off.
NOTE
Please complete the
warranty card
6.3. Fault identification and troubleshooting
Fault
Cause
Solution
Pump not working
No power
Check that mains plug is plugged in
Pump is faulty
Replace pump
Pump not pumping
Liquid level in drum is too
Check liquid level, if necessary
low
ask IBS Scherer to change the drum
Pump is faulty
Replace pump
If the steps described above do not resolve the problem,
please contact IBS Scherer GmbH.
6.4.
Personal protective equipment
When handling solvents, protective clothing must be worn in accordance with the safety data
sheet for the industrial cleaner used. Solvent-resistant gloves, safety glasses and aprons must
be used with all IBS Special Cleaning Agents.
Glove material:
-
Gloves made from polychloroprene (CR), recommended material thickness: > 0.5 mm, max.
breakthrough time: 4 hours
-
Gloves made from nitrile rubber/nitrile latex (NBR), recommended material thickness:
> 0.35 mm
-
Gloves made from fluororubber (Viton) (FKM), recommended material thickness: > 0.4 mm
Permeation rate/breakthrough time: > 8 hours (DIN EN 374)
The exact breakthrough time must be ascertained from the protective glove manufacturer and
must be observed. Protective gloves should be replaced when they show the first signs of wear.
7. Maintenance / cleaning
__________________________________________________
7.1.
Maintenance / cleaning work
The mains plug must be removed before carrying out any maintenance or cleaning work.