background image

 

2.3. Non-approved cleaning agents 

 

 

 

 

Halogenated solvents 

 

Flammable and highly flammable solvents with flash point < 55°C, except for cleaning 
agents with flash point > 40°C when technical ventilation (exhaust system) is installed 

 

 

 
 

2.4. Standards 

 

Always comply with EN 12921-1 and EN 12921-3. 

 
 

3. Operating principle

 _________________________________________________________ 

 

 

3.1.

 

How the machine works 

The IBS pump pumps the cleaning liquid through a hose to the IBS cleaning brush. The 
workpiece is placed on the support rack and is cleaned with the brush and cleaning liquid. 

 

 

The dirty cleaning agent flows back into the drum. The dirt particles sink to the bottom of the 
drum. When the cleaning effect of the cleaning agent declines, the drum must be replaced 
with a new drum of IBS Special Cleaning Agent. 
 

 

3.2.

 

Safety information 

See section 6 

 
 

4. Transport

  _________________________________________________________________________ 

 

 

4.1.

 

Handling

 

  Take great care when transporting the device to the installation site at the customer's 

premises in order to prevent damage. 

  Secure the device on the pallet to ensure that it does not slip off. 

  When transporting the drum, read and follow the data sheet for the solvent. 

 

4.2.

 

Transport aids 
4.2.1. Transport using a crane 

  Attach the crane cables to the pallet and lift the device carefully. Pay special attention to the 

centre of gravity. The device may tip. 

 

NOTE

 

 

The crane must have a carrying capacity of at least 200 kg. 

 

4.2.2. Transport using a fork-lift 

  Insert the fork-lift between the longitudinal pieces on the wooden pallet.

 

  Lift the unit and transport it.

 

 
 
 
 

Summary of Contents for M

Page 1: ...Original operating instructions IBS Parts Cleaning Device Type M Type MD All devices have been tested and certified Visit our website www ibs scherer com ...

Page 2: ...vice stability 3 5 2 Space required 3 5 3 Acceptable ambient conditions 3 5 4 Preventing electrostatic charge 3 5 4 1 IBS pump 3 5 4 1 1 Parts Cleaning Device 3 5 4 1 2 Electrical connection by the customer 3 5 5 Additional equipment 3 5 5 1 IBS collecting tray 3 5 5 2 IBS exhaust system 3 5 6 Disposal 3 5 7 Precautionary measures to be taken by the operator 4 6 Operating the machine 5 6 1 Control...

Page 3: ...roper use _______________________________________________________________________ The IBS Parts Cleaning Device has been designed for cleaning of oily and greasy metal parts e g machine parts motors and housings using IBS Special Cleaning Agents 2 1 Approved cleaning agents IBS Special Cleaning Agent Type EL Extra IBS Special Cleaning Agent Type RF IBS Special Cleaning Agent Type Purgasol IBS Spec...

Page 4: ... the cleaning agent declines the drum must be replaced with a new drum of IBS Special Cleaning Agent 3 2 Safety information See section 6 4 Transport _________________________________________________________________________ 4 1 Handling Take great care when transporting the device to the installation site at the customer s premises in order to prevent damage Secure the device on the pallet to ensu...

Page 5: ...ut by a qualified electrician 5 4 1 2 Electrical connection by the customer Installation at the customer s premises must be carried out by an approved electrician in accordance with VDE requirements and any applicable power supply company regulations The electrical supply line must be installed in accordance with the regulations and must comply with the information Technical data given in the oper...

Page 6: ...IBS recommends a danger area of 1 m around the device The danger area identified by means of a risk assessment Must be designated a fire hazard area Must remain free of obstructions in order to allow unimpeded access at all times Must be equipped with effective natural ventilation Smoking is not permitted in the danger area Naked flames or other sources of ignition are not permitted in the danger ...

Page 7: ...e pump 8 into the drum and screw the 2 threaded plug 16 into the drum Ensure that the pump outflow 12 is facing to the left and the terminal box is facing towards the rear Insert the return hose 9 into the hole in the 2 threaded plug 16 Attach the top end of the return hose 9 to the outlet connector 10 on the tray and secure it with the hose clip supplied Attach the brush hose 11 to the pump outle...

Page 8: ...vents protective clothing must be worn in accordance with the safety data sheet for the industrial cleaner used Solvent resistant gloves safety glasses and aprons must be used with all IBS Special Cleaning Agents Glove material Gloves made from polychloroprene CR recommended material thickness 0 5 mm max breakthrough time 4 hours Gloves made from nitrile rubber nitrile latex NBR recommended materi...

Page 9: ...ack slatted rack 2222016 Support rack slatted rack 2222062 Support rack slatted rack 2222008 Cleaning brush fine 50 mm bristles 2222009 Cleaning brush coarse 50 mm bristles 2222022 Foot operated switch with cover 2222024 Foot operated switch without cover 2222026 Wheel 1 only 2221012 Return hose 2222033 Return connector 2222035 Threaded plug return connector 2 2222059 Brush hose Item no Descriptio...

Reviews: