5
6. Operating the machine
6.1.
Controls
The device is switched on with a foot-operated safety switch.
6.2.
Assembly and adjustment
6.2.1. Assembling the Parts Cleaning Device
•
We advise a two-man assembly to avoid damaging during the assembly of the Parts-
Cleaner-Type M/MD
•
Remove the packaging
•
Insert the two base frames
(1)
into the round pipe sleeves
(2)
(located directly underneath
the tray).
•
Attach the two cross braces
(3)
to the base frames using the bolts supplied
(4)
.
•
Place the 200-litre drum
(5)
in the collecting tray (optional)
(6)
with the screw fitting facing
upwards and remove the 2” bung adapter in the drum casing.
•
Place the assembled device over the drum
(5)
6.2.2. Assembling the IBS special pump
•
Tilt the drum
(5)
slightly. Insert the pump
(8)
into the drum and screw the 2” threaded plug
(16
)
into the drum.
Ensure that the pump outflow
(12)
is facing to the left and the terminal box is facing towards
the rear.
•
Insert the return hose
(9)
into the hole in the 2” threaded plug
(16)
.
•
Attach the top end of the return hose
(9)
to the outlet connector
(10)
on the tray and secure
it with the hose clip supplied.
•
Attach the brush hose
(11)
to the pump outlet
(12
)
.
•
Feed the brush hose
(11)
through the round hole in the rear wall of the tray
(13)
and insert
the cleaning brush
(14)
.
•
Place the foot-operated safety switch
(7)
in front of the device.
•
Connect the device to the customer’s equipotential bonding system (see section 5.4.1.2).
Use the earth connection cables supplied to connect the Parts Cleaning device to the drum
and collecting tray.
•
Insert the plug
(15)
into the 230 V socket.
•
Perform a function test: cleaning liquid must flow when the foot switch is pressed.
Pump, complete
12
8
7
15
14
16