is set, you must enter the administrator password, not the power-on
password, to run the diagnostic programs.
2.
When the message
F2 for Diagnostics
appears, press F2.
3.
Type in the appropriate password; then, press Enter.
4.
Select either
Extended
or
Basic
from the top of the screen.
5.
When the Diagnostic Programs screen appears, select the test you want to run
from the list that appears; then, follow the instructions on the screen.
Notes:
a.
If the server stops during testing and you cannot continue, restart the server
and try running the diagnostic programs again.
b.
The keyboard and mouse (pointing device) tests assume that a keyboard
and mouse are attached to the server.
c.
If you run the diagnostic programs with either no mouse or a USB mouse
attached to your server, you will not be able to navigate between test
categories using the
Next Cat
and
Prev Cat
buttons. All other functions
provided by mouse-selectable buttons are also available using the function
keys.
d.
You can test the USB keyboard by using the regular keyboard test. Also,
you can run the USB Interface test only if there are no USB devices
attached.
e.
You can view server configuration information (such as system
configuration, memory contents, interrupt request (IRQ) use, direct memory
access (DMA) use, device drivers, and so on) by selecting
Hardware Info
from the top of the screen.
When the tests have completed, you can view the Test Log by selecting
Utility
from the top of the screen.
If the hardware checks out OK but the problem persists during normal server
operations, a software error might be the cause. If you suspect a software problem,
refer to the information that comes with the software package.
Viewing the test log
The test log will not contain any information until after the diagnostic program has
run.
Note:
If you already are running the diagnostic programs, begin with step 3
To view the test log:
1.
Turn on the server and watch the screen.
If the server is on, shut down your operating system and restart the server.
2.
When the message
F2 for Diagnostics
appears, press F2.
If a power-on password or administrator password is set, the server prompts
you for it. Type in the appropriate password; then, press Enter.
3.
When the Diagnostic Programs screen appears, select
Utility
from the top of
the screen.
4.
Select
View Test Log
from the list that appears; then, follow the instructions on
the screen.
The system maintains the test-log data while the server is powered on. When
you turn off the power to the server, the test log is cleared.
Diagnostics
15
Summary of Contents for xSeries 342 2RX
Page 1: ...Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 2: ......
Page 3: ...Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 110: ...102 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 114: ...106 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 127: ...Related service information 119...
Page 128: ...120 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 129: ...Related service information 121...
Page 130: ...122 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 131: ...Related service information 123...
Page 132: ...124 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 133: ...Related service information 125...
Page 134: ...126 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 147: ...Related service information 139...
Page 148: ...140 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 149: ...Related service information 141...
Page 157: ......