Error Code/Symptom
FRU/Action
1600
(The Service Processor is not
functioning) Do the following before
replacing a FRU:
1.
Ensure that a jumper is not installed
on J45.
2.
Remove the ac power to the system,
wait 20 seconds; then, re-connect the
ac power. Wait 30 seconds; then,
power-on the system.
1.
System Board
1601
(The system is able to communicate
to the Service Processor, but the Service
Processor failed to respond at the start of
POST.) Do the following before replacing
a FRU:
1.
Remove the ac power to the system,
wait 20 seconds; then, re-connect the
ac power. Wait 30 seconds; then,
power-on the system.
2.
Flash update the Service Processor.
1.
System Board
1762
(Fixed Disk Configuration error)
1.
Fixed Disk Drive
2.
Fixed Disk Cables
3.
Run Configuration/Setup
4.
Fixed Disk Adapter
5.
SCSI Backplane
6.
System Board
178X
(Fixed Disk error)
1.
Fixed Disk Cables
2.
Run Diagnostics
3.
Fixed Disk Adapter
4.
Fixed Disk Drive
5.
System Board
1800
(No more hardware interrupt
available for PCI adapter)
1.
Run Configuration/Setup
2.
Failing Adapter
3.
System Board
1962
(Drive does not contain a valid boot
sector)
1.
Verify a bootable operating system is installed.
2.
Run Diagnostics
3.
Hard Disk Drive
4.
SCSI Backplane
5.
Cable
6.
System Board
2400
(Video controller test failure)
1.
Video Adapter (if installed)
2.
System Board
2462
(Video memory configuration error)
1.
Video Adapter (if installed)
2.
System Board
94
Hardware Maintenance Manual: xSeries 342 Model 1RX, 2RX, 1TG, 2TG
Summary of Contents for xSeries 342 2RX
Page 1: ...Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 2: ......
Page 3: ...Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 110: ...102 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 114: ...106 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 127: ...Related service information 119...
Page 128: ...120 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 129: ...Related service information 121...
Page 130: ...122 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 131: ...Related service information 123...
Page 132: ...124 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 133: ...Related service information 125...
Page 134: ...126 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 147: ...Related service information 139...
Page 148: ...140 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 149: ...Related service information 141...
Page 157: ......