Power error messages
Message
Action
Power supply
″
X
″
current share fault
(nonlevel-critical; excessive current demand
on power supply
″
X
″
)
1.
Replace power supply
″
X
″
Power supply
″
X
″
DC good fault
(level-critical; power good signal not
detected for power supply
″
X
″
)
1.
Replace power supply
″
X
″
Power supply
″
X
″
temperature fault
1.
Replace power supply
″
X
″
Power supply
″
X
″
removed
1.
No action required - information only
Power supply
″
X
″
fan fault
(level-critical;
fan fault in power supply
″
X
″
)
1.
Replace power supply
″
X
″
Power supply
″
X
″
12V fault
(level-critical;
overcurrent condition detected)
1.
See “Power checkout” on page 19.
Power supply
″
X
″
3.3V fault
(level-critical;
3.3V power supply
″
X
″
had an error)
1.
See “Power checkout” on page 19.
Power supply
″
X
″
5V fault
(level-critical; 5V
power supply
″
X
″
had an error)
1.
See “Power checkout” on page 19.
System running non-redundant power
(level-non-critical; system does not have
redundant power)
1.
Add another power supply
2.
Remove options from system
3.
System can continue to operate without redundancy protection if
1
and
2
above are not followed.
System under recommended voltage for
″
X
″
v
(level-warning; indicated voltage
supply under nominal value; value for
″
X
″
can be +12, -12, or +5)
1.
Check connections to power subsystem
2.
Replace power supply
3.
Replace power backplane
System shutdown
Refer to the following tables when experiencing system shutdown related to
voltage or temperature problems.
Voltage related system shutdown
Message
Action
System shutoff due to
″
X
″
current over
max value
(level-critical; system drawing
too much current on voltage
″
X
″
bus)
1.
See “Power checkout” on page 19.
System shutoff due to
″
X
″
V over voltage
(level-critical; system shutoff due to
″
X
″
supply over voltage)
1.
Check power supply connectors
2.
Replace power supply
3.
Replace power backplane
System shutoff due to
″
X
″
V under
voltage
(level-critical system shutoff due to
″
X
″
supply under voltage)
1.
Check power supply connectors
2.
Replace power supply
3.
Replace power backplane
System shutoff due to VRM
″
X
″
over
voltage
1.
Replace VRM
″
X
″
98
Hardware Maintenance Manual: xSeries 342 Model 1RX, 2RX, 1TG, 2TG
Summary of Contents for xSeries 342 2RX
Page 1: ...Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 2: ......
Page 3: ...Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 110: ...102 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 114: ...106 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 127: ...Related service information 119...
Page 128: ...120 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 129: ...Related service information 121...
Page 130: ...122 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 131: ...Related service information 123...
Page 132: ...124 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 133: ...Related service information 125...
Page 134: ...126 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 147: ...Related service information 139...
Page 148: ...140 Hardware Maintenance Manual xSeries 342 Model 1RX 2RX 1TG 2TG...
Page 149: ...Related service information 141...
Page 157: ......