v
Hot-case
upgrade
—
The
DS4000
EXP700s
and
connected
storage
server
remain
powered
on
when
ESMs
are
replaced.
You
should
schedule
the
upgrade
during
non-peak
I/O
period.
Use
the
DS4000
Storage
Manager
performance
monitor
function
to
determine
the
non-peak
I/O
load
time
if
required.
Note:
It
is
recommended
that
you
schedule
the
hot-case
ESM
upgrade
during
a
non-peak
(low-usage)
I/O
period
for
the
following
reasons:
–
The
DS4000
storage
server
drive
loops/channels
will
be
disturbed
with
FC
Loop
Initialization
events
every
time
the
ESM
is
replaced.
–
One
of
the
drive
loops
in
the
drive
loop
will
be
down
during
the
upgrade,
reducing
the
maximum
data
bandwidth
to
the
drives
by
one-half.
Important
After
a
DS4000
EXP700
is
upgraded
with
the
DS4000
EXP700
Models
1RU/1RX
Switched-ESM
Option
Upgrade
Kit,
it
is
considered
a
DS4000
EXP710
for
the
purposes
of
cabling
your
drive
loop.
Therefore,
if
you
are
not
upgrading
all
the
DS4000
EXP700
storage
expansion
enclosures
in
a
drive
loop,
you
must
follow
the
intermixing
requirements
for
redundant
drive
loops
that
include
both
DS4000
EXP700s
and
DS4000
EXP710s.
These
requirements
state
that
all
DS4000
EXP710s
in
a
redundant
drive
loop
must
be
grouped
together.
See
Cold-case
ESM
upgrade
procedure
In
the
cold-case
ESM
upgrade
procedure,
you
must
power
down
the
storage
subsystem
before
upgrading
the
DS4000
EXP700
ESMs.
If
your
environment
does
not
allow
you
to
power
down
the
storage
subsystem
in
a
non-emergency
situation,
use
the
Note:
The
cold-case
ESM
upgrade
procedure
is
recommended
if
you
are
intermixing
DS4000
EXP700s
and
DS4000
EXP710s
in
the
same
drive
loop.
Attention:
If
you
are
not
upgrading
all
of
the
DS4000
EXP700s
in
the
redundant
drive
loop,
or
if
you
are
upgrading
additional
DS4000
EXP700s
in
redundant
drive
loop
that
includes
both
DS4000
EXP700s
and
DS4000
EXP710s,
you
must
follow
the
intermixing
requirements
for
drive
loops
that
include
both
DS4000
EXP700s
and
DS4000
EXP710s.
See
Failure
to
do
so
can
result
in
drive
loop
performance
problems
due
to
excessive
time-outs
and
LIPs.
1.
Before
you
begin
the
upgrade
procedure,
perform
a
full
system
backup
and
save
the
storage
subsystem
profile.
2.
Upgrade
the
Storage
Manager
client
to
version
9.1
or
later.
3.
Upgrade
the
ESM
firmware
for
all
DS4000
EXP700s
to
version
9326
or
later.
4.
Upgrade
the
controller
firmware
to
version
6.10.xx.xx
or
later.
Attention:
No
I/O
activity
can
be
present
during
the
firmware
upgrade
from
version
5.4x.xx.xx
or
earlier
to
version
6.10.xx.xx
or
later.
5.
After
you
have
upgraded
the
Storage
Manager
client
and
controller
firmware,
verify
that
the
storage
server
is
in
optimal
condition.
Use
the
Recovery
Guru
function
in
the
Storage
Manager
client
Subsystem
Management
window
for
information
on
how
to
fix
any
non-optimal
conditions.
86
IBM
TotalStorage
DS4000
EXP700
and
EXP710
Storage
Expansion
Enclosures:
Installation,
User’s,
and
Maintenance
Guide