Power
supply
The
DS4400
Storage
Server
power
system
consists
of
two
power
supplies.
The
power
supplies
slide
into
either
of
the
two
slots
on
the
back
of
the
DS4400
Storage
Server.
The
power
supplies
provide
power
to
the
internal
components
by
converting
incoming
ac
voltage
to
dc
voltage.
The
power
supplies
are
interchangeable
and
redundant.
Each
power
supply
uses
one
power
cord.
You
can
plug
both
power
cords
into
a
common
power
source
or
plug
each
cord
into
a
separate
circuit
for
power
redundancy.
One
power
supply
can
maintain
electrical
power
to
the
DS4400
Storage
Server
if
the
other
power
supply
is
turned
off
or
malfunctions.
Servicing
notes
Consider
the
following
when
servicing
the
power
supplies:
v
Each
power
supply
has
a
built-in
sensor
that
detects
the
following
conditions:
–
Overvoltage
–
Overcurrent
–
Overtemperature
If
any
of
these
conditions
occur,
one
or
both
power
supplies
enter
shutdown
mode.
All
power
remains
off
until
one
of
the
following
occurs:
–
You
cycle
the
power
switches
(turn
off
the
power
switches,
wait
at
least
30
seconds,
then
turn
on
the
power
switches).
For
more
information,
see
“Overtemperature
condition
and
power
supply
shutdown”
on
page
36.
–
The
power
supplies
automatically
resume
operation
when
the
ambient
air
temperature
cools
to
below
70°
C
(158°
F).
When
the
power
supplies
automatically
resume
operation,
the
DS4400
Storage
Server
also
resumes
operation.
v
You
can
hot
swap
(replace)
a
power
supply
because
the
two
power
supplies
provide
redundancy.
v
Both
power
supplies
have
built-in
temperature
sensors
designed
to
prevent
the
power
supplies
from
overheating.
If
a
temperature
sensor
detects
an
ambient
air
temperature
greater
than
70°
C
(158°
F),
the
“overheated”
power
supply
automatically
shuts
down.
The
second
power
supply
remains
on
as
long
as
its
temperature
remains
below
70°
C
(158°
F).
If
the
second
power
supply
overheats,
it
turns
off
all
power
to
the
DS4400
Storage
Server.
Note:
There
is
a
serious
problem
if
the
air
temperature
inside
the
rack
cabinet
is
hot
enough
to
cause
the
power
supplies
to
shut
down.
v
The
DS4400
Storage
Server
is
capable
of
power-up
recovery
without
operator
intervention.
Once
the
air
temperature
cools
to
below
70°
C
(158°
F),
the
power
supplies
automatically
restart.
An
automatic
restart
resets
the
controllers,
attempts
to
restart
the
hard
disk
drives,
which
has
no
effect
on
the
hard
disk
drives
if
they
are
already
running,
and
returns
the
DS4400
Storage
Server
to
normal
operation.
v
When
a
power
supply
fails,
the
green
power
indicator
light
on
the
power
supply
goes
off
and
the
amber
power
supply
fault
light
is
lit
on
the
front
of
the
DS4400
Storage
Server.
For
more
information,
see
“Power
supply
indicator
light”
on
page
33
and
“Storage
server
indicator
lights”
on
page
28.
v
If
you
replace
the
power
supply
CRU
and
still
experience
problems,
the
DS4400
Storage
Server
might
have
defective
components
or
connections.
Check
the
storage-management
software
for
indications
of
other
component
failures.
Chapter
3.
Replacing
DS4400
Storage
Server
components
55
Summary of Contents for TotalStorage DS4400
Page 1: ...IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide GC26 7730 00...
Page 2: ......
Page 3: ...IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide GC26 7730 00...
Page 7: ...Glossary 75 75 Index 85 Contents v...
Page 8: ...vi IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Page 10: ...viii IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Page 12: ...x IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Page 18: ...xvi IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Page 32: ...xxx IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Page 52: ...20 IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Page 98: ...66 IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Page 106: ...74 IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Page 116: ...84 IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Page 120: ...88 IBM TotalStorage DS4400 Fibre Channel Storage Server User s Guide...
Page 123: ......
Page 124: ...Printed in USA GC26 7730 00...