Symptom/Error
FRU/Action in Sequence
Battery can’t be charged.
v
Go to “Power systems checkout” on
page 36.
v
Battery assembly
v
System board
Memory-Related Symptom
Symptom/Error
FRU/Action in Sequence
Memory count (size)
appears different from
the actual size.
v
Go to “FRU tests” on page 60.
v
Enter BIOS Utility and execute
″
Load Setup Default Settings
″
; then
reboot the system.
v
DIMM
v
System board
Audio-Related Symptoms
Symptom/Error
FRU/Action in Sequence
Internal speakers make
noise or emit no sound.
v
Speaker volume control
v
Go to “FRU tests” on page 60.
v
Speaker(s)
External speakers make
noise or emit no sound.
v
Speaker volume control
v
Go to “FRU tests” on page 60.
v
Speaker(s)
In DOS or Windows,
multimedia programs, no
sound comes from the
computer. (Only system
beeps are heard at
power-on.)
v
Speaker volume control
v
Go to “FRU tests” on page 60.
v
Speaker(s)
PC Card (PCMCIA)-Related Symptoms
Symptom/Error
FRU/Action in Sequence
System cannot detect the
PC Card (PCMCIA)
v
PC Card (PCMCIA) holder
assembly
v
System board
PCMCIA slot pin is
damaged.
PC Card (PCMCIA) holder assembly
MT 2658/2659/2677
51
Summary of Contents for ThinkPad R32 2658
Page 1: ...ThinkPad R32 Series Hardware Maintenance Manual...
Page 4: ...iv ThinkPad R32 Series...
Page 85: ...1 Step Size Quantity Color Torque 1 M2 5 x L10 7 Black 3 2 kgf cm MT 2658 2659 2677 79...
Page 103: ...MT 2658 2659 2677 97...
Page 145: ...1 Step Size Quantity Color Torque 1 M2 5 x L10 7 Black 3 2 kgf cm MT 2658 2659 2677 139...
Page 205: ...1 Step Size Quantity Color Torque 1 M2 5 x L10 7 Black 3 2 kgf cm MT 2658 2659 2677 199...