background image

Combining high-performance architecture with high-performance Xeon processors

 

 

 

Please see the Legal Information section for important notices and information. 

times

 the maximum throughput of a 133MHz PCI-X adapter

3

. (A 

x1

 adapter offers throughput 

similar to a 

66MHz

 PCI-X slot.) 

Because the 

SAS

ServeRAID-MR10k

, dual 

Gigabit Ethernet

, and 

systems management

 

controllers are integrated onto the system board, the seven adapter slots are all 

available

, which 

offers you a wide degree of latitude in expansion options. 
(Even though the HP DL580G5 has eleven total slots, they offer lower throughput, providing no 
more aggregate bandwidth than the seven slots of the eX4 servers.) 

 

Dual Gigabit Ethernet Controller 

The eX4 systems include one integrated 

dual-port Broadcom 5709C 

Gigabit Ethernet 

controller, with

 TOE

 (TCP Offload Engine) acceleration support (available 1Q/08), as well as 

load-balancing

 and 

failover

 capabilities between the two ports. 

TOE

 support helps improve overall system performance by offloading TCP/IP protocol 

processing from the system microprocessor to the onboard Ethernet TOE processor. 

iSCSI

 

support works similarly for iSCSI workloads. 
The controller also supports highly secure remote power management using 

IPMI

 

2.0

, plus 

Wake on LAN

®

 and 

PXE

 (Preboot Execution Environment) flash interface. Optional PCI 

adapters offering failover and load balancing between adapters are available for added 
throughput and increased system availability.

 

 

Ultra-Efficient Cooling 

Six

 strategically located 

hot-swap/redundant

 fans, combined with efficient airflow paths, 

provide highly effective system cooling for the eX4 systems, known as 

Calibrated Vectored 

Cooling

. The fans are arranged to cool 

three separate zones

, left, center, and right, with one 

pair of redundant fans per zone. 
The fans automatically adjust speeds in response to changing thermal requirements, depending 
on the zone, redundancy, and internal temperatures. When the temperature inside the server 
increases, the fans speed up to maintain the proper ambient temperature. When the 
temperature returns to a normal operating level, the fans return to their default speed. Why not 
simply run the fans at 100% capacity all the time? For several good reasons: to reduce the 
ambient noise, reduce the wear-and-tear on the fans and reduce the server power draw. The 
reduction in ambient noise and power draw may be relatively minor for a single server, but if you 
have a larger number of systems the aggregate savings in power and noise pressure can be 
significant. 
In addition, the server uses 

hexagonal ventilation holes

 in the chassis. Hexagonal holes can 

be grouped more densely than round holes, providing greater airflow through the system cover. 
This cooling scheme is important because newer, more powerful processors generate a 
significant amount of heat, and heat must be controlled for the system to function properly. 

 

Hot-Swap/Redundant Components 

System availability is maximized through the extensive use of hot-swap and redundant 
components, including: 

 

Hot-add/hot-swap redundant memory

 protection (with 

Chipkill, Memory ProteXion

and selectable 

memory mirroring

 capabilities) 

 

Hot-swap redundant hard disk drives

 (with standard

 LSI 1078

 controller and optional 

ServeRAID-MR10k

 providing multiple levels of RAID support) 

 

Hot-swap PCIe adapter slots

 (with optional failover support) 

 

Hot-swap redundant cooling fans

 (three redundant pairs) 

 

Hot-swap redundant power supplies

4

 

 

Light Path Diagnostics 

Light path diagnostics enables a technician to quickly identify and locate a failed or failing 
system component, such as a specific memory DIMM. (Monitored components include 
processors, memory, power supplies, fans, HDDs, adapters, and voltage regulator modules 
(VRMs), plus system temperature.) This enables quick replacement of the component, which 
helps increase server uptime and lower operating costs.  
The front of the server has an LED indicator light to show possible component failures. If the 

                                                                                                                                                                                                    

2

 Variable read rate. Actual playback speed varies and is often less than the maximum possible. 

3

 Actual throughput will depend on the adapter vendor’s implementation. 

4

 At 220V both power supplies are redundant; at 110V only the first power supply is redundant. 

Summary of Contents for System x3850 M2

Page 1: ...and running in a virtualized environment faster and easier than ever before IBM X Architecture pioneered XpandOnDemand pay as you grow scalability which allows chassis to be simply cabled together to...

Page 2: ...nced features help maximize network availability by increasing uptime as do hot swap redundant HDDs power and fans Active Memory temperature controlled fans with Calibrated Vectored Cooling IPMI 2 0 s...

Page 3: ...per core 80W quad core Xeon processor models E7320 at 2 13GHz with 64 bit extensions low power draw per core 20W quad 1066MHz FSBs and 4MB of L2 cache 2 x 2MB 1MB per core 80W dual core Xeon processor...

Page 4: ...ther architectures Intel now offers a first generation snoop filter in their 7300 chipset however it contains only 64MB of RAM which is 80 smaller than the eX4 fourth generation solution Advanced Buff...

Page 5: ...king latency In addition it also offers innovative data reliability and security features to help improve data integrity including enhanced CRC protection data retry on error detect and buffer registe...

Page 6: ...SI SAS controller This controller supports up to four internal SAS LVD low voltage differential drives The integrated SAS controller offers hardware RAID 0 1 support for those SAS drives The ServeRAID...

Page 7: ...n the proper ambient temperature When the temperature returns to a normal operating level the fans return to their default speed Why not simply run the fans at 100 capacity all the time For several go...

Page 8: ...1000 SVGA video controller on the Remote Supervisor Adapter II provides up to 1024x768 resolution with a color depth of 32 bits at 85Hz refresh rate with 16MB of video memory Toolless slides Allows qu...

Page 9: ...em temperature fans power supplies processor and DIMM status Fan speed control Product ID and Family ID detection Highly secure remote power on off System reset control NMI SMI detection and generatio...

Page 10: ...and Capacity Manager sold separately are available as add ons for additional server management and increased availability IBM Systems Director provides a single uniform graphical interface for all of...

Page 11: ...u take your servers to a higher level You can rely on System x options to supply a complete solution for your business needs Options help you create an optimized server system to meet your data protec...

Page 12: ...tional integrated ServeRAID MR10k SAS SATA controller offers enhanced performance over the integrated LSI 1078 SAS controller 256MB of battery backed cache memory and supports seven RAID levels 0 stri...

Page 13: ...ew Redundant H S Power Supply Bays PCIe Slots Video Port Scalability Ports Hot swap PCIe slots USB Ports Serial Port Remote Supervisor Adapter II Gb Ethernet Ports Hexagonal Ventilation Holes SAS Port...

Page 14: ...r chassis Internal L2 cache 9MB 3 x 3MB 7233 7234 all 8MB 2 x 4MB 7141 7144 1xX 1xY 4xX 4xY 6MB 2 x 3MB 7141 7144 3xX 3xY 4MB 2 x 2MB 7141 7144 2xX 2xY External L3 cache 16MB shared cache 7233 6xX 6xY...

Page 15: ...1 External disk drives supported standard Yes via external 4 port SAS connector External disk storage devices supported System Storage DS4100 DS4200 DS4300 DS4400 DS4500 DS4700 DS4800 DS6800 DS8100 DS...

Page 16: ...ating systems supported 7141 7144 Microsoft Windows Server 2003 R2 Standard Web Enterprise Editions 32 64 bit RHEL 4 AS ES 32 64 bit RHEL 5 Server 32 64 bit SLES 9 10 32 64 bit VMware ESX Server 3 0 2...

Page 17: ...AS drives internally and one external SAS port for optional external storage per chassis up to 16 drives in a 4 chassis configuration High performance external I O expansion Six 480Mbps USB 2 0 ports...

Page 18: ...gal Information section for important notices and information 18 Hot swap redundant cooling Light path diagnostics front LED panel drop down light path panel Toolless chassis and toolless slide design...

Page 19: ...emarks or registered trademarks of Microsoft Corporation Other company product and service names may be trademarks or service marks of others WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INC...

Reviews: