background image

Combining high-performance architecture with high-performance Xeon processors

 

 

 

Please see the Legal Information section for important notices and information. 

twice as many FSBs as before and each is 

60%

 faster than before. 

Intel 

Extended Memory 64 Technology (EM64T)

 64-bit extensions allow the Xeon processor 

to use large memory addressing when running with a 64-bit operating system. This in turn lets 
individual software processes directly access more than 4GB of RAM, which was the limit of 32-
bit addressing. This can result in much higher performance for certain kinds of programs, such 
as database management and CAD. Additional registers and instructions (SSE3) can further 
boost performance for applications written to use them. Customers should contact their software 
provider to determine their software support for EM64T. 
Intel’s

 Virtualization Technology

 (VT) integrates hardware-level virtualization hooks that allow 

operating system vendors to better utilize the hardware for virtualization workloads, a key 
workload for the eX4 platform. 

 
 
 

eX4 Chipset ‘Snoop’ Filtering 

One of the core features of the eX4 chipset that gives the platform a performance advantage is 
the snoop filter. The Xeon Coherency Protocol or “snoop” is an operation that occurs whenever 
a processor in an SMP system needs to update a memory address during normal operation. 
The snoop occurs when the processor getting ready to operate on a piece of data asks the other 
processors in the SMP complex to verify they have not modified the same piece of data without 
writing back from their cache. This operation increases traffic on the front side bus. 
The eX4 chipset contains 

324MB

 of EDRAM within the Northbridge chip. This copies all data as 

it is written to the processor cache, allowing the chipset to respond directly to the snoop 
requests. This reduces the overall traffic across the FSB and helps to improve system 
performance over other architectures. (Intel now offers a first-generation snoop filter in their 
7300 chipset; however it contains only 64MB of RAM which is 

80% smaller

 than the eX4 fourth-

generation solution.) 

 
 
 

Advanced Buffer eXecution 

The IBM Advanced Buffer 
eXecution (ABX) chips (2 per 
chassis) provide the x3850 M2 / 
3950 M2’s DDR2 memory with 
up to 

60%

 more bandwidth than 

other vendors can manage using 
more expensive (and more 
energy-hungry) Fully Buffered 
DIMMs (FB-DIMMs). The ABX 
chip uses two buffers per 
memory card to re-drive the 
signals from the eX4 memory 
controller to the DIMMs, 
bypassing the latency-adding 
buffers used on each FB-DIMM. 
The use of ABX 

reduces 

latency by 20%

 vs. FB-DIMMs. 

This feature is a unique IBM 
enhancement, not offered by 
other x86 server architectures 
(using either Intel or AMD processors). 

 
 
 

XceL4v Dynamic Server Cache 

Another performance feature of the eX4 chipset is the XceL4v L4 cache. When using a single 
node (chassis), the cache works with the snoop filter to help reduce FSB traffic. When 

more

 

than one node is used, 

256MB

 of virtual cache 

per node

 (taken from main memory) is used for 

interprocessor communications between chassis, to keep data in synch. In a 4chassis 
configuration, this amounts to as much as 

1GB 

of L4 cache. This not only compensates for any 

performance hit that might otherwise result from sending data across the distances between 
processors in multiple chassis, it actually results in a performance improvement versus a single 
chassis. (IBM X3 and eX4 servers have achieved well over 100 #1 results on industry-standard 
benchmarks, such as TPC-C, TPC-E, TPC-H, SAP SD, vConsolidate, Vmark, and more.) 
This feature is a unique IBM enhancement, not offered by other x86 server architectures (using 
either Intel or AMD processors). 

Scalable Virtual L4 

cache 

IB: 2 x12 

533 
MT/s 

1066 MT/s 

2.5 GT/s 

SP: 3 x8 

2.1 
GT/s 

I

A

3

P

r

o

I

A

3

P

r

o

I

A

3

P

r

o

I

A

3

P

r

o

LP

ES

South 

Bridge 

I/F 

Memory 

DIMMS 

Flash  

I/F 

 
 
 

eX4 chipset 

N

o
v

x

N

o
v

x

N

o
v

x

N

o
v

x

N

o
v

x

N

o
v

x

N

o
v

x

N

o
v

x

Summary of Contents for System x3850 M2

Page 1: ...and running in a virtualized environment faster and easier than ever before IBM X Architecture pioneered XpandOnDemand pay as you grow scalability which allows chassis to be simply cabled together to...

Page 2: ...nced features help maximize network availability by increasing uptime as do hot swap redundant HDDs power and fans Active Memory temperature controlled fans with Calibrated Vectored Cooling IPMI 2 0 s...

Page 3: ...per core 80W quad core Xeon processor models E7320 at 2 13GHz with 64 bit extensions low power draw per core 20W quad 1066MHz FSBs and 4MB of L2 cache 2 x 2MB 1MB per core 80W dual core Xeon processor...

Page 4: ...ther architectures Intel now offers a first generation snoop filter in their 7300 chipset however it contains only 64MB of RAM which is 80 smaller than the eX4 fourth generation solution Advanced Buff...

Page 5: ...king latency In addition it also offers innovative data reliability and security features to help improve data integrity including enhanced CRC protection data retry on error detect and buffer registe...

Page 6: ...SI SAS controller This controller supports up to four internal SAS LVD low voltage differential drives The integrated SAS controller offers hardware RAID 0 1 support for those SAS drives The ServeRAID...

Page 7: ...n the proper ambient temperature When the temperature returns to a normal operating level the fans return to their default speed Why not simply run the fans at 100 capacity all the time For several go...

Page 8: ...1000 SVGA video controller on the Remote Supervisor Adapter II provides up to 1024x768 resolution with a color depth of 32 bits at 85Hz refresh rate with 16MB of video memory Toolless slides Allows qu...

Page 9: ...em temperature fans power supplies processor and DIMM status Fan speed control Product ID and Family ID detection Highly secure remote power on off System reset control NMI SMI detection and generatio...

Page 10: ...and Capacity Manager sold separately are available as add ons for additional server management and increased availability IBM Systems Director provides a single uniform graphical interface for all of...

Page 11: ...u take your servers to a higher level You can rely on System x options to supply a complete solution for your business needs Options help you create an optimized server system to meet your data protec...

Page 12: ...tional integrated ServeRAID MR10k SAS SATA controller offers enhanced performance over the integrated LSI 1078 SAS controller 256MB of battery backed cache memory and supports seven RAID levels 0 stri...

Page 13: ...ew Redundant H S Power Supply Bays PCIe Slots Video Port Scalability Ports Hot swap PCIe slots USB Ports Serial Port Remote Supervisor Adapter II Gb Ethernet Ports Hexagonal Ventilation Holes SAS Port...

Page 14: ...r chassis Internal L2 cache 9MB 3 x 3MB 7233 7234 all 8MB 2 x 4MB 7141 7144 1xX 1xY 4xX 4xY 6MB 2 x 3MB 7141 7144 3xX 3xY 4MB 2 x 2MB 7141 7144 2xX 2xY External L3 cache 16MB shared cache 7233 6xX 6xY...

Page 15: ...1 External disk drives supported standard Yes via external 4 port SAS connector External disk storage devices supported System Storage DS4100 DS4200 DS4300 DS4400 DS4500 DS4700 DS4800 DS6800 DS8100 DS...

Page 16: ...ating systems supported 7141 7144 Microsoft Windows Server 2003 R2 Standard Web Enterprise Editions 32 64 bit RHEL 4 AS ES 32 64 bit RHEL 5 Server 32 64 bit SLES 9 10 32 64 bit VMware ESX Server 3 0 2...

Page 17: ...AS drives internally and one external SAS port for optional external storage per chassis up to 16 drives in a 4 chassis configuration High performance external I O expansion Six 480Mbps USB 2 0 ports...

Page 18: ...gal Information section for important notices and information 18 Hot swap redundant cooling Light path diagnostics front LED panel drop down light path panel Toolless chassis and toolless slide design...

Page 19: ...emarks or registered trademarks of Microsoft Corporation Other company product and service names may be trademarks or service marks of others WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INC...

Reviews: