speed
is set to
Max performance
and
LV-DIMM power
is set to
Enhance
performance
mode. The 1.35 V UDIMMs, RDIMMs or LRDIMMs will function
at 1.5 V.
v
The server supports a maximum of 16 dual-rank UDIMMs. The server supports
up to two UDIMMs per channel.
v
The server supports a maximum of 24 single-rank, dual-rank, or 16 quad-rank
RDIMMs. The server does not support three quad-rank RDIMMs in the same
channel.
v
The following table shows an example of the maximum amount of memory that
you can install using ranked DIMMs:
Table 7. Maximum memory installation using ranked DIMMs
Number of
DIMMs
DIMM type
DIMM size
Total memory
16
Dual-rank UDIMMs
4 GB
64 GB
24
Single-rank RDIMMs
2 GB
48 GB
24
Single-rank RDIMMs
4 GB
96 GB
24
Dual-rank RDIMMs
8 GB
192 GB
24
Dual-rank RDIMMs
16 GB
384 GB
24
Quad-rank HCDIMMs
32 GB
768 GB
16
Quad-rank RDIMMs
16 GB
256 GB
24
Quad-rank LRDIMMs
32 GB
768 GB
v
The UDIMM option that is available for the server is 4 GB. The server supports a
minimum of 4 GB and a maximum of 64 GB of system memory using UDIMMs.
v
The RDIMM options that are available for the server are 2 GB, 4 GB, 8 GB, and
16 GB. The server supports a minimum of 2 GB and a maximum of 384 GB of
system memory using RDIMMs.
v
The HCDIMM options that are available for the server are 16 GB and 32 GB.
The server supports a minimum of 16 GB and a maximum of 768 GB of system
memory using HCDIMMs.
Note:
Do not mix the 16 GB HCDIMM and the 32 GB HCDIMM in the server.
v
The LRDIMM option that is available for the server is 32 GB. The server supports
a minimum of 32 GB and a maximum of 768 GB of system memory using
LRDIMMs.
Note:
The amount of usable memory is reduced depending on the system
configuration. A certain amount of memory must be reserved for system
resources. To view the total amount of installed memory and the amount of
configured memory, run the Setup utility. For additional information, see
Chapter 3, “Configuring the server,” on page 141.
v
A minimum of one DIMM must be installed for each microprocessor. For
example, you must install a minimum of two DIMMs if the server has two
microprocessors installed. However, to improve system performance, install a
minimum of four DIMMs for each microprocessor.
v
DIMMs in the server must be the same type (RDIMM, UDIMM, or LRDIMM) to
ensure that the server will operate correctly.
v
When you install one quad-rank DIMM in a channel, install it in the DIMM
connector furthest away from the microprocessor.
Chapter 2. Installing optional devices
109
Summary of Contents for System x3650 M4 Type 7915
Page 1: ...System x3650 M4 Type 7915 Installation and User s Guide...
Page 2: ......
Page 3: ...System x3650 M4 Type 7915 Installation and User s Guide...
Page 8: ...vi System x3650 M4 Type 7915 Installation and User s Guide...
Page 17: ...CAUTION Hazardous moving parts are nearby Safety xv...
Page 18: ...xvi System x3650 M4 Type 7915 Installation and User s Guide...
Page 48: ...30 System x3650 M4 Type 7915 Installation and User s Guide...
Page 113: ...Port 20 23 Port 16 19 Adapter SAS signal cables Chapter 2 Installing optional devices 95...
Page 158: ...140 System x3650 M4 Type 7915 Installation and User s Guide...
Page 184: ...166 System x3650 M4 Type 7915 Installation and User s Guide...
Page 190: ...172 System x3650 M4 Type 7915 Installation and User s Guide...
Page 191: ......
Page 192: ...Part Number 00V9884 Printed in USA 1P P N 00V9884...