1. Read the safety information that begins on page vii and “Installation guidelines”
on page 40.
2. Turn off the server and disconnect all power cords and external cables (see
“Turning off the server” on page 28).
3. Remove the server cover (see “Removing the cover” on page 54).
4. Remove the two 4-drive filler panels that are to the right of drive bay 8,
beneath the IDs 8 - 15 on the front bezel.
4-drive
filler panel
5. To obtain more working room, remove fans 2 and 3 (see “Removing a
dual-motor hot-swap fan” on page 123).
6. Install the new backplane assemblies.
eXFlash 1.8-inch drive cage
and backplane assembly
7. Connect the following cables in the order listed:
v
Configuration cable
1
v
SAS signal cables
2
v
Power cable
3
92
System x3650 M4 Type 7915: Installation and User’s Guide
Summary of Contents for System x3650 M4 Type 7915
Page 1: ...System x3650 M4 Type 7915 Installation and User s Guide...
Page 2: ......
Page 3: ...System x3650 M4 Type 7915 Installation and User s Guide...
Page 8: ...vi System x3650 M4 Type 7915 Installation and User s Guide...
Page 17: ...CAUTION Hazardous moving parts are nearby Safety xv...
Page 18: ...xvi System x3650 M4 Type 7915 Installation and User s Guide...
Page 48: ...30 System x3650 M4 Type 7915 Installation and User s Guide...
Page 113: ...Port 20 23 Port 16 19 Adapter SAS signal cables Chapter 2 Installing optional devices 95...
Page 158: ...140 System x3650 M4 Type 7915 Installation and User s Guide...
Page 184: ...166 System x3650 M4 Type 7915 Installation and User s Guide...
Page 190: ...172 System x3650 M4 Type 7915 Installation and User s Guide...
Page 191: ......
Page 192: ...Part Number 00V9884 Printed in USA 1P P N 00V9884...