Code (H)
Description
Panel
Indication
00B8
accessor error #1.
Reverse REV position (PP1) error (accessor
origin not detected or FWD position
detected). Suspect the P origin sensor, FWD
sensor, or P motor.
CHK 00B8
1. Check the accessor locking screw and remove it if it is installed. See
2. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library
operations resume. See
.
If the problem persists, see
Contacting IBM technical support
00B9
accessor error #2.
Forward FWD position (PP2) error (accessor
origin detected or FWD not detected).
Suspect the P origin sensor, FWD sensor, or P
motor.
CHK 00B9
00BA
accessor error #3.
PUT/GET/bar code reader position
(PP4/PP5/PPBF/PPBR) error (accessor origin
or FWD detected, or cell full). Suspect the P
origin sensor, FWD sensor, or P motor.
CHK 00BA
00BC
During initialization, the accessor origin is
not detected. Suspect the P origin sensor,
FWD sensor, or P motor.
CHK 00BC
00BD
During accessor movement, the movement
stop condition is detected. Suspect the P
encoder sensor or P motor.
CHK 00BD
00BF
No gap condition detected at the completion
of accessor operation. Suspect the centering
sensor, P origin sensor, FWD sensor, or P
motor.
CHK 00BF
00C0
accessor operation disabled because a
cartridge magazine was removed. Suspect
the magazine set sensor.
CHK 00C0
1. Confirm that the magazine is closed.
2. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library
operations resume. See
.
If the problem persists, see
Contacting IBM technical support
00C8
Centering calibration error #1.
During centering calibration, centering
sensor OFF condition is not detected.
Suspect the centering sensor or P motor.
CHK 00C8
Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library operations
resume. See
.
If the problem persists, see
Contacting IBM technical support
00C9
Centering calibration error #2.
During centering calibration, centering
sensor ON condition is not detected. Suspect
the centering sensor, X motor, or P motor.
CHK 00C9
00D0
Checksum error detected during firmware
update.
CHK 00D0
1. Confirm the firmware file version.
2. Reinstall the firmware file.
3. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library
operations resume. See
.
If the problem persists, see
Contacting IBM technical support
00D1
Firmware ID error detected during firmware
update.
CHK 00D1
00D2
Boot information error detected during
firmware update.
CHK 00D2
00D3
Bar code reader is not in maintenance mode
during bar code reader firmware update
(operation interrupted). Suspect the bar code
reader cable connection.
CHK 00D3
1. Initiate an inventory. See
.
2. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library
operations resume. See
.
If the problem persists, see
Contacting IBM technical support
00D9
Magazine failed to unlock. Suspect the
magazine or magazine sensor.
CHK 00D9
1. Cycle the power supply and try again.
2. Manually unlock the magazine, remove the magazine from the library, and
inspect it for damage.
If not damaged, return it to the library and run Library Verify before
normal library operations resume. See
.
If damaged, replace the magazine.
00DA
I/O Station failed to unlock. Suspect the
magazine or magazine sensor.
CHK 00DA
00DD
An error detected during bar code reader
firmware check. Suspect the bar code reader
cable connection.
CHK 00DD
1. Initiate an inventory. See
.
2. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library
operations resume. See
.
If the problem persists, see
Contacting IBM technical support
00E0
Write operation not finished within 1 ms
when writing data to flash memory.
CHK 00E0
Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library operations
resume. See
.
If the problem persists, see
Contacting IBM technical support
00E1
Clear operation not finished within 10
seconds when clearing a sector in flash
memory.
CHK 00E1
00E2
Error detected in tape library configuration
stored in flash memory.
CHK 00E2
00E3
Checksum error detected in flash memory.
CHK 00E3
60
TS2900 Tape Autoloader
Summary of Contents for System Storage TS2900
Page 1: ...TS2900 Tape Autoloader IBM...