Location: P1.1-I3/Q1-W5003013D38321011-L1000000000000
VPD:
Manufacturer................IBM
Machine Type and Model......3572-TL
Serial Number...............X2U78B0384
Device Specific.(FW)........4.09 (Firmware Level)
Description
TAPE DRIVE FAILURE
Probable Causes
TAPE DRIVE
Failure Causes
TAPE
TAPE DRIVE
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Detail Data
aabb xxxx ccdd eeee eeee eeee eeee eeee ffgg hhxx ssss ssss ssss ssss ssss ....
aa Length of the Command Descriptor Block (CDB) sent by the host. In this case,
“0C” bytes.
bb SCSI target address. In this example, SCSI address “00”.
xx Unused or reserved.
cc Start of CDB, cc is the operation code (byte 0). In this case, “A5” which
was an “Move Medium”.
SENSE DATA
0C00 0000 A500 0000 100F 1010 0000 0000 0102 0000 7000 0400 0000 000A 0000 0000
818F 0000 BE00 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
Table 1. Library sense data example
Hex
Description
A5
SCSI Command (in this case Move Medium).
70
Byte 0 of Library Sense Data (Valid Data).
04
Sense Key (in this case Hardware Error).
818F
ASC/ASCQ (extra sense code/additional sense code qualifier), in this case a “Cannot Find Slider Block” error.
SCSI sense data - tape drive error
The following example of SCSI Sense Data was received from a System p Open System host and shows a Tape Drive Failure and what the sense data would look like. Like
the SCSI sense data in the previous example, this data contains valid sense data as defined by the hex “71” in the first sense byte position. Therefore, there is valid data to
rely on. While the data shows a TAPE_ERR2, further review of the ASC/ASCQ (Media Load or Eject Failed) points more to a problem with the media or the drive. The fact
that a FID was listed ("86") defines the failure as "The drive detected a drive hardware or media fault". In this case, follow the FID to make a repair. For more information
about Sense Key and ASC/ASCQ fields, see the IBM LTO Ultrium Tape Drive SCSI Reference.
LABEL: TAPE_ERR2
IDENTIFIER: 476B351D
Date/Time: Wed May 09 07:51:42 DFT
Sequence Number: 1669
Machine Id: 0046083B4C00
Node Id: risc4
Class: H
Type: PERM
Resource Name: rmt0 Resource Class: tape Resource Type: LTO
Location: P1.1-I3/Q1-W5003013D38321011-L0
VPD:
Manufacturer................IBM
Machine Type and Model......ULT3573-TD4
Serial Number...............1300000680
Device Specific.(FW)........74H4 (Firmware Level)
Loadable Microcode Level....A1700D5C
Description
TAPE DRIVE FAILURE
Probable Causes
TAPE DRIVE
Failure Causes
TAPE
TAPE DRIVE
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Detail Data
SENSE DATA
0600 0000 0000 0000 0000 0000 0000 0000 0102 0000 7100 0400 0000 0058 0000 0000
5300 8602 8E07 0000 0001 0110 0001 0000 0000 0000 0200 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 2800 01E0 0000 0000 0000 4133 3820
TS2900 Tape Autoloader
103
Summary of Contents for System Storage TS2900