background image

Collect and record the following required infrastructure information

v

NTP Server/s IP address (Windows NTP Servers are
not supported)

v

DNS servers IP address

v

Public network subnets (subnets used for NAS traffic,
example: 99.99.99.0/24)

v

Public network IP addresses (IP used by clients to
connect to the Storwize V7000 Unified NAS services, 1
for each file module is recommended, example
99.99.99.100,99.99.99.101)

v

Public network gateway IP Address

v

Authentication server details (available options are
LDAP, NIS, Active Directory or utilize the built-in
authentication server)

v

System name (DNS hostname for the Storwize V7000
Unified management IP, example: officenas1)

v

Domain name (example: mycompany.com)

v

DNS search domains (additional domain names to be
used with the primary domain name, example:
backup.mycompany.com, if used the primary domain
must also be added)

Install the hardware in the rack and connect the cables (minimum quantities are
given)

v

1x 2U Storwize V7000 storage control enclosure

v

2x 2U Storwize V7000 Unified file modules

v

1x Ethernet Network Switch

v

A

10x Cat5e Ethernet cables

v

B

4x LC – LC Fiber cables

v

1x Laptop able to access the Storwize V7000 Unified
management IP.

Follow the guidelines on racking the equipment from the
online documentation Information Center,
http://pic.dhe.ibm.com/infocenter/storwize/unified_ic/
Ensure that each Storwize V7000 Unified file module has
a Fibre Channel cable to both the upper and lower
canister

Cabling diagram connecting the file modules, control
enclosure, and Ethernet switch.

CAUTIO N

CAU

TIO

N

CAUT

IO

N

CAUT I O N

Disconnect all
supply power for
complete isolation

Disconnect all
supply power for
complete isolation

Disconnect all

supply power for

complete isolation

Disconnect all

supply power for

complete isolation

1

2

3

4

5

6

1

2

3

4

5

6

V7000 Unified File Module 1

V7000 Unified File Module 2

V7000 Storage Control Enclosure

(upper node canister)

(lower node canister)

A

B

ifs00076

Ethernet switch or switches

Note that in the default configuration,

A

Ethernet

connections on each Storwize V7000 Unified file module
are bonded so each pair of cables and must be plugged
into the same Ethernet switch.

2

IBM Storwize V7000 Unified: Model 2073-720 Quick Start Guide