background image

Connecting the cables from the control enclosure to the expansion units (total
time 20 minutes)

If you have expansion enclosures then connect them as
shown.

Cabling diagram connecting the control enclosure to one
or more expansion units.

CAUTIO N

CAU

TIO

N

CAUT

IO

N

CAUT I O N

Disconnect all
supply power for
complete isolation

Disconnect all
supply power for
complete isolation

Disconnect all

supply power for

complete isolation

Disconnect all

supply power for

complete isolation

CAUTIO N

CAU

TIO

N

CAUT

IO

N

CAUT I O N

Disconnect all
supply power for
complete isolation

Disconnect all
supply power for
complete isolation

Disconnect all

supply power for

complete isolation

Disconnect all

supply power for

complete isolation

CAUTIO N

CAU

TIO

N

CAUT

IO

N

CAUT I O N

Disconnect all
supply power for
complete isolation

Disconnect all
supply power for
complete isolation

Disconnect all

supply power for

complete isolation

Disconnect all

supply power for

complete isolation

CAUTIO N

CAU

TIO

N

CAUT

IO

N

CAUT I O N

Disconnect all
supply power for
complete isolation

Disconnect all
supply power for
complete isolation

Disconnect all

supply power for

complete isolation

Disconnect all

supply power for

complete isolation

CAUTIO N

CAU

TIO

N

CAUT

IO

N

CAUT I O N

Disconnect all
supply power for
complete isolation

Disconnect all
supply power for
complete isolation

Disconnect all

supply power for

complete isolation

Disconnect all

supply power for

complete isolation

1 2

A

B

6

5

C

ifs00062

3

4

8

7

Initialize the Storwize V7000 Unified software, using the USB flash drive (total time
80 minutes)

First, Initialize the Storwise V7000 storage control
enclosure

Both the upper node canister and the lower node
canister of the Storwize V7000 storage control enclosure
should have a solid green light and a blinking green
light before continuing, consult the online Information
Center if the system is not ready after 10 minutes.

Insert the USB flash drive which was prepared earlier
into the upper node canister. The upper node canister
will show 2 solid green lights and an amber light, after
1-2 minutes and once the amber light turns off, remove
the USB flash drive.

Place the USB flash drive in the laptop, it should contain
the files NAS.ppk and satask_result.html among others.
Consult the online Information Center if they are
missing.

Second, Initialize the Storwise V7000 Unified file
modules

Both of the Storwize V7000 Unified file modules should
have a blinking blue light before continuing. Ensure
there are no disks in the DVD drives before continuing.

Insert the USB flash drive into one of the file modules,
the blue blinking light on that file module will go solid.
Wait 1-2 minutes then open a Web browser and navigate
to the Storwize V7000 Unified management IP:

This initialization can take up to 75 minutes.

Configure the Storwize V7000 Unified software, SAN block storage (total time 5
minutes)

1.

Navigate to the Storwize V7000 Unified management

IP with a Web browser.

2.

Login with the default admin password of

admin

.

Then read and accept the license agreement.

3.

Next, configure the system attributes, enter the

System

name

,

NetBIOS name

, and

Time Zone

: The NetBIOS

name is what the NAS client sees when using
CIFS/SMB/Windows shares.

4.

Now, verify hardware, ensure all the storage hardware

has been detected. Configure storage by selecting

Automatically configure internal storage

and then click

Finish

.

IBM

®

Storwize V7000 Unified Model 2073-720 Quick Start Guide

3