Power consumption (maximum configuration)
Model name @100 VAC
input
@200 VAC
input
@48 VDC input Minimum
number of
power supplies
Notes
SAN64B-6
switch
2.07 A
204 W
696 BTU/hr
1.03 A
202 W
690 BTU/hr
N/A
2 (But, input
current is for 1
PSU. Watts and
BTUs/hr are with
2 PSUs).
Fully configured all ports with
100% traffic rate, fans at high
speed, and input power +/- 5%
tolerance.
Power consumption (idle configuration)
Model
name
@100 VAC
input
@200 VAC
input
@48 VDC input Minimum
number of
power supplies
Notes
SAN64B-6
switch
1.54 A
155 W
529 BTU/hr
0.77 A
154 W
526 BTU/hr
N/A
1 (But, input
current is for 1
PSU. Watts and
BTUs/hr are with
2 PSUs).
All optics loaded but not
initialized and the system
completed boot up, fans at
nominal speed, and input
power +/- 5% tolerance.
Data port specifications (Fibre Channel)
Name
Port
Numbers
Media Type
Description
SAN64B-6
switch
0 to 47
10-, 16-, or 32-Gbps SFP+
optical ports
Can be an F_Port, N_Port, E_Port, or EX_Port
48 to 63
4 x 16-Gbps (64 Gbps) or 4
x 32-Gbps (128 Gbps)
QSFP optical ports
Can be an E_Port or EX_Port
Fibre Channel data transmission ranges
Port speed
(Gbps)
Cable size
(microns)
Short wavelength
(SWL)
Long wavelength
(LWL)
Extended long
wavelength (ELWL)
4
50
150 m (492 ft) (OM2)
380 m (1,264 ft) (OM3)
400 m (1,312 ft) (OM4)
N/A
N/A
62.5
70 m (229 ft)
N/A
N/A
9
N/A
30 km (18.6 miles)
N/A
Appendix A. Product specifications 85
Summary of Contents for SAN64B-6
Page 6: ...vi...
Page 10: ...x...
Page 22: ...xxii IBM Storage Networking SAN64B 6 SAN64B 6 Installation Service and User Guide...
Page 60: ...36 IBM Storage Networking SAN64B 6 SAN64B 6 Installation Service and User Guide...
Page 70: ...46 IBM Storage Networking SAN64B 6 SAN64B 6 Installation Service and User Guide...
Page 84: ...60 IBM Storage Networking SAN64B 6 SAN64B 6 Installation Service and User Guide...
Page 92: ...68 IBM Storage Networking SAN64B 6 SAN64B 6 Installation Service and User Guide...
Page 121: ......
Page 122: ...IBM Part Number 03GM380 SC27 8965 02 1P P N 03GM380...