should perform the installation and service procedures. The switch can continue
operating during the FRU replacement if you follow the steps in the procedure.
The switch has two power supplies (
3
and
4
in Figure 17).
1
Switch chassis
3
Power supply #1
2
Non-port side
4
Power supply #2
Time required
Less than 2 minutes
Items required
v
New power supply
v
Phillips #1 screwdriver
DANGER
Hazardous voltage, current, or energy levels are present
inside any component that has this label attached. (L001)
Do not service, there are no serviceable parts.
Procedure
Note:
To leave the switch in service during replacement of a power supply, verify
that the other power supply (the one not being replaced) has been powered
on for at least four seconds and has a steady green LED.
Complete the following steps to remove and replace a power supply.
Scale: 1/8" = 1"
Scale:
5/16" = 1"
4
2
1
3
b32e4012
Figure 17. Power supply locations
Chapter 3. Using and maintaining the switch
37
Summary of Contents for SAN32B-E4
Page 2: ......
Page 8: ...vi SAN32B E4 Installation Service and User Guide ...
Page 12: ...x SAN32B E4 Installation Service and User Guide ...
Page 14: ...xii SAN32B E4 Installation Service and User Guide ...
Page 24: ...xxii SAN32B E4 Installation Service and User Guide ...
Page 34: ...8 SAN32B E4 Installation Service and User Guide ...
Page 56: ...30 SAN32B E4 Installation Service and User Guide ...
Page 74: ...48 SAN32B E4 Installation Service and User Guide ...
Page 80: ...54 SAN32B E4 Installation Service and User Guide ...
Page 88: ...62 SAN32B E4 Installation Service and User Guide ...
Page 91: ......
Page 92: ... Part Number 45W8661 Printed in USA GA32 0798 00 1P P N 45W8661 ...