About this task
The 2145-92F expansion enclosure supports 92 drives. Figure 81 on page 74 shows an example of a
drive assembly.
Figure 81. Drive assembly
1
Disk drive
2
Online indicator
3
Fault indicator
4
Release latch
5
Drive latch toes
6
Drive carrier
Procedure
1. Read all the available safety information.
2. Remove the cover, as described in “Removing the top cover: 2145-92F ” on page 56.
3. Locate the empty drive slot to receive the new drive or that contains the faulty drive that you want to
replace.
Note: When a drive is faulty, the amber fault indicator is lit (
3
in Figure 81 on page 74). Do not
replace a drive unless the drive fault indicator is on or you are instructed to do so by a fix procedure.
A label on the enclosure cover (Figure 82 on page 74) shows the drive locations in the enclosure.
The drive slots are numbered 1-14 from left to right and A-G from the back to the front of the
enclosure.
Figure 82. Drive locations in a 5U expansion enclosure
74 SAN Volume Controller : Model 2145-SV1 Hardware Installation Guide
Summary of Contents for SAN Volume Controller 2145-12F
Page 1: ...IBM SAN Volume Controller Hardware Installation Guide IBM...
Page 6: ...vi...
Page 48: ...16 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 62: ...30 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 72: ...40 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 168: ...136 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 176: ...144 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 178: ...146 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 182: ...150 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 192: ...160 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 193: ......
Page 194: ...IBM...