background image

Notices

This information was developed for products and services offered in the US.

IBM may not offer the products, services, or features discussed in this document in other countries.
Consult your local IBM representative for information on the products and services currently available in
your area. Any reference to an IBM product, program, or service is not intended to state or imply that
only that IBM product, program, or service may be used. Any functionally equivalent product, program,
or service that does not infringe any IBM intellectual property right may be used instead. However, it is
the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or
service.

IBM may have patents or pending patent applications covering subject matter described in this
document. The furnishing of this document does not grant you any license to these patents. You can send
license inquiries, in writing, to:

IBM Director of Licensing
IBM Corporation
North Castle Drive, MD-NC119
Armonk, NY 10504-1785
US

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS"
WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or
implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically
made to the information herein; these changes will be incorporated in new editions of the publication.
IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.

Any references in this information to non-IBM websites are provided for convenience only and do not in
any manner serve as an endorsement of those websites. The materials at those websites are not part of
the materials for this IBM product and use of those websites is at your own risk.

IBM may use or distribute any of the information you provide in any way it believes appropriate without
incurring any obligation to you.

The performance data and client examples cited are presented for illustrative purposes only. Actual
performance results may vary depending on specific configurations and operating conditions.

Information concerning non-IBM products was obtained from the suppliers of those products, their
published announcements or other publicly available sources. IBM has not tested those products and
cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM
products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of
those products.

Statements regarding IBM's future direction or intent are subject to change or withdrawal without notice,
and represent goals and objectives only.

© Copyright IBM Corp. 2015

17

Summary of Contents for PurePower System

Page 1: ...Power Systems Installing your IBM PurePower System IBM ...

Page 2: ......

Page 3: ...Power Systems Installing your IBM PurePower System IBM ...

Page 4: ...on in the safety and environmental notices included with the system This edition applies to the IBM PureFlex System and to all subsequent releases and modifications until otherwise indicated in new editions Copyright IBM Corporation 2015 US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp ...

Page 5: ...wer System with multiple racks 1 Connecting power cords and verifying that the system attention LEDs are green 12 Using the rack mounted keyboard and monitor to access the PurePower Integrated Manager user interface 14 Completing the installation 15 Notices 17 Trademarks 18 Electronic emission notices 18 Class A Notices 18 Class B Notices 23 Terms and conditions 26 Copyright IBM Corp 2015 iii ...

Page 6: ...iv Power Systems Installing your IBM PurePower System ...

Page 7: ...roduct The documentation contains the safety information in your national language with references to the U S English source Before using a U S English publication to install operate or service this product you must first become familiar with the related safety information documentation You should also refer to the safety information documentation any time you do not clearly understand any safety ...

Page 8: ...the machine meets safety requirements v Do not continue with the inspection if any unsafe conditions are present v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructed otherwise in the installation and configuration procedures v Connect and disconnect cables as described in the following procedures when installing mo...

Page 9: ...nt temperature for all your rack mounted devices v Do not install a unit in a rack where the air flow is compromised Ensure that air flow is not blocked or reduced on any side front or back of a unit used for air flow through the unit v Consideration should be given to the connection of the equipment to the supply circuit so that overloading of the circuits does not compromise the supply wiring or...

Page 10: ...minate potential hazards v Verify that the route that you choose can support the weight of the loaded rack cabinet Refer to the documentation that comes with your rack cabinet for the weight of a loaded rack cabinet v Verify that all door openings are at least 760 x 230 mm 30 x 80 in v Ensure that all devices shelves drawers doors and cables are secure v Ensure that the four leveling pads are rais...

Page 11: ...DANGER Rack mounted devices are not to be used as shelves or work spaces L002 L003 or or 1 2 3 4 or Safety notices ix ...

Page 12: ...power cords The product might be equipped with multiple power cords To remove all hazardous voltages disconnect all power cords L003 L007 CAUTION A hot surface nearby L007 L008 x Power Systems Installing your IBM PurePower System ...

Page 13: ...ptacle Although shining light into one end and looking into the other end of a disconnected optical fiber to verify the continuity of optic fibers many not injure the eye this procedure is potentially dangerous Therefore verifying the continuity of optical fibers by shining light into one end and looking at the other end is not recommended To verify continuity of a fiber optic cable use an optical...

Page 14: ...ush or lean Keep riser tilt option flat at all times except for final minor adjustment when needed v Do not stand under overhanging load v Do not use on uneven surface incline or decline major ramps v Do not stack loads v Do not operate while under the influence of drugs or alcohol v Do not support ladder against LIFT TOOL v Tipping hazard Do not push or lean against load with raised platform v Do...

Page 15: ...e interfaces that connect to the OSP outside plant or its wiring These interfaces are designed for use as intrabuilding interfaces only Type 2 or Type 4 ports as described in GR 1089 CORE and require isolation from the exposed OSP cabling The addition of primary protectors is not sufficient protection to connect these interfaces metallically to OSP wiring Note All Ethernet cables must be shielded ...

Page 16: ...xiv Power Systems Installing your IBM PurePower System ...

Page 17: ...panels on any compute nodes display 01 N PVM 10 If you ordered IBM Systems Lab Services for startup services and basic network integration you would stop here and let IBM Systems Lab Services complete the remaining steps while training your personnel 11 You access the rack mounted monitor and keyboard that is preinstalled in the rack 12 You access the PurePower Integrated Manager by double clickin...

Page 18: ...ox SX1710 2 U21 Port 1 QSFP DAC cable Aggregation switch rack Mellanox SX1710 1 user determined Port 3 Rack 1 Mellanox SX1710 2 U21 Port 2 QSFP DAC cable Aggregation switch rack Mellanox SX1710 2 user determined Port 3 Rack 1 Mellanox SX1710 2 U21 Port 3 QSFP DAC cable Aggregation switch rack Mellanox SX1710 1 user determined Port 4 Rack 1 Mellanox SX1710 2 U21 Port 4 QSFP DAC cable Aggregation sw...

Page 19: ...rack Mellanox SX1710 1 user determined Port 11 Rack 3 Mellanox SX1710 2 U21 Port 2 QSFP DAC cable Aggregation switch rack Mellanox SX1710 2 user determined Port 11 Rack 3 Mellanox SX1710 2 U21 Port 3 QSFP DAC cable Aggregation switch rack Mellanox SX1710 1 user determined Port 12 Rack 3 Mellanox SX1710 2 U21 Port 4 QSFP DAC cable Aggregation switch rack Mellanox SX1710 2 user determined Port 12 Ra...

Page 20: ...Mellanox SX1710 1 user determined Port 19 Rack 5 Mellanox SX1710 2 U21 Port 2 QSFP DAC cable Aggregation switch rack Mellanox SX1710 2 user determined Port 19 Rack 5 Mellanox SX1710 2 U21 Port 3 QSFP DAC cable Aggregation switch rack Mellanox SX1710 1 user determined Port 20 Rack 5 Mellanox SX1710 2 U21 Port 4 QSFP DAC cable Aggregation switch rack Mellanox SX1710 2 user determined Port 20 Rack 6 ...

Page 21: ...h rack Mellanox SX1710 1 user determined Port 27 Rack 7 Mellanox SX1710 2 U21 Port 2 QSFP DAC cable Aggregation switch rack Mellanox SX1710 2 user determined Port 27 Rack 7 Mellanox SX1710 2 U21 Port 3 QSFP DAC cable Aggregation switch rack Mellanox SX1710 1 user determined Port 28 Rack 7 Mellanox SX1710 2 U21 Port 4 QSFP DAC cable Aggregation switch rack Mellanox SX1710 2 user determined Port 28 ...

Page 22: ...termined Port 0 Rack 1 IBM SAN48B 5 1 U16 Port 1 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 1 user determined Port 1 Rack 1 IBM SAN48B 5 1 U16 Port 2 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 1 user determined Port 2 Rack 1 IBM SAN48B 5 1 U16 Port 3 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 1 user determined Port 3 Rack 1 IBM SAN48B 5 2 U17 Port 0 OM3 MMF cable Aggregatio...

Page 23: ...egation switch rack IBM SAN48B 5 1 user determined Port 9 Rack 3 IBM SAN48B 5 1 U16 Port 2 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 1 user determined Port 10 Rack 3 IBM SAN48B 5 1 U16 Port 3 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 1 user determined Port 11 Rack 3 IBM SAN48B 5 2 U17 Port 0 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 2 user determined Port 8 Rack 3 IBM SA...

Page 24: ...n switch rack IBM SAN48B 5 1 user determined Port 17 Rack 5 IBM SAN48B 5 1 U16 Port 2 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 1 user determined Port 18 Rack 5 IBM SAN48B 5 1 U16 Port 3 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 1 user determined Port 19 Rack 5 IBM SAN48B 5 2 U17 Port 0 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 2 user determined Port 16 Rack 5 IBM SAN48B...

Page 25: ...regation switch rack IBM SAN48B 5 1 user determined Port 25 Rack 7 IBM SAN48B 5 1 U16 Port 2 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 1 user determined Port 26 Rack 7 IBM SAN48B 5 1 U16 Port 3 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 1 user determined Port 27 Rack 7 IBM SAN48B 5 2 U17 Port 0 OM3 MMF cable Aggregation switch rack IBM SAN48B 5 2 user determined Port 24 Rack 7 IBM...

Page 26: ... 1 U18 Port 36 Cat5e or higher rated cable Aggregation switch rack Lenovo G8052 switch 2 user determined Port 1 Rack 1 Lenovo G8052 switch 2 U19 Port 45 Cat5e or higher rated cable Aggregation switch rack Lenovo G8052 switch 1 user determined Port 2 Rack 1 Lenovo G8052 switch 2 U19 Port 36 Cat5e or higher rated cable Aggregation switch rack Lenovo G8052 switch 2 user determined Port 2 Rack 2 Lenov...

Page 27: ...switch 1 user determined Port 9 Rack 5 Lenovo G8052 switch 1 U18 Port 36 Cat5e or higher rated cable Aggregation switch rack Lenovo G8052 switch 2 user determined Port 9 Rack 5 Lenovo G8052 switch 2 U19 Port 45 Cat5e or higher rated cable Aggregation switch rack Lenovo G8052 switch 1 user determined Port 10 Rack 5 Lenovo G8052 switch 2 U19 Port 36 Cat5e or higher rated cable Aggregation switch rac...

Page 28: ...er determined Port 16 Rack 8 Lenovo G8052 switch 2 U19 Port 36 Cat5e or higher rated cable Aggregation switch rack Lenovo G8052 switch 2 user determined Port 16 Aggregation switch rack Lenovo G8052 switch 1 user determined Port 46 Cat5e or higher rated cable Aggregation switch rack Lenovo G8052 switch 2 user determined Port 46 Aggregation switch rack Lenovo G8052 switch 1 user determined Port 47 C...

Page 29: ...ntify the components in your system see Identifying hardware components in an IBM PurePower System If one of your components isn t responding correctly see Troubleshooting the hardware components Figure 1 System attention LED locations Figure 2 Operator panel display Installing your IBM PurePower System 13 ...

Page 30: ...nge the required fields Note To change the password for the PurePower Integrated Manager operating system puremgrvm complete the following steps a From the Red Hat Enterprise Linux RHEL KVM operating system desktop select Applications Utilities Terminal b From the terminal session run the following command ssh admin 192 168 93 46 PASSW0RD c From the puremgrvm operating system run the following com...

Page 31: ... of the startup services while training your personnel You might want to do the following after the IBM Service Team representative leaves your site v Learn more about PurePower Integrated Manager v Add components For more information about the configuration and management tasks that you can perform see Configuring and managing your system http www ibm com support knowledgecenter POWER8 p8ef9 p8ef...

Page 32: ...16 Power Systems Installing your IBM PurePower System ...

Page 33: ...therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication IBM may make improvements and or changes in the product s and or the program s described in this publication at any time without notice Any references...

Page 34: ...ical operations Users should periodically check IBM s support websites for updated information and fixes applicable to the system and related software Homologation statement This product may not be certified in your country for connection by any means whatsoever to interfaces of public telecommunications networks Further certification may be required by law prior to making any such connection Cont...

Page 35: ...que de la classe A est conforme à la norme NMB 003 du Canada European Community Compliance Statement This product is in conformity with the protection requirements of EU Council Directive 2004 108 EC on the approximation of the laws of the Member States relating to electromagnetic compatibility IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a...

Page 36: ...tatement This statement explains the Japan JIS C 61000 3 2 product wattage compliance This statement explains the Japan Electronics and Information Technology Industries Association JEITA statement for products less than or equal to 20 A per phase This statement explains the JEITA statement for products greater than 20 A single phase This statement explains the JEITA statement for products greater...

Page 37: ... need to perform practical action Electromagnetic Interference EMI Statement Taiwan The following is a summary of the EMI Taiwan statement above Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user will be required to take adequate measures IBM Taiwan Contact Information Electromagnetic Interference EMI Statement Korea Notices...

Page 38: ...all kann vom Betreiber verlangt werden angemessene Maßnahmen zu ergreifen und dafür aufzukommen Deutschland Einhaltung des Gesetzes über die elektromagnetische Verträglichkeit von Geräten Dieses Produkt entspricht dem Gesetz über die elektromagnetische Verträglichkeit von Geräten EMVG Dies ist die Umsetzung der EU Richtlinie 2004 108 EG in der Bundesrepublik Deutschland Zulassungsbescheinigung lau...

Page 39: ... following measures v Reorient or relocate the receiving antenna v Increase the separation between the equipment and receiver v Connect the equipment into an outlet on a circuit different from that to which the receiver is connected v Consult an IBM authorized dealer or service representative for help Properly shielded and grounded cables and connectors must be used in order to meet FCC emission l...

Page 40: ... were derived for typical residential environments to provide reasonable protection against interference with licensed communication equipment European Community contact IBM Deutschland GmbH Technical Regulations Department M372 IBM Allee 1 71139 Ehningen Germany Tele 49 0 800 225 5423 or 49 0 180 331 3233 email halloibm de ibm com VCCI Statement Japan Japan Electronics and Information Technology ...

Page 41: ...than 20 A per phase three phase IBM Taiwan Contact Information Electromagnetic Interference EMI Statement Korea Germany Compliance Statement Deutschsprachiger EU Hinweis Hinweis für Geräte der Klasse B EU Richtlinie zur Elektromagnetischen Verträglichkeit Notices 25 ...

Page 42: ...es Corp New Orchard Road Armonk New York 10504 Tel 914 499 1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist IBM Deutschland GmbH Technical Regulations Abteilung M372 IBM Allee 1 71139 Ehningen Germany Tel 49 0 800 225 5423 or 49 0 180 331 3233 email halloibm de ibm com Generelle Informationen Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse B Terms ...

Page 43: ... export or re export this information except in full compliance with all applicable laws and regulations including all United States export laws and regulations IBM MAKES NO GUARANTEE ABOUT THE CONTENT OF THESE PUBLICATIONS THE PUBLICATIONS ARE PROVIDED AS IS AND WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY NON INFRINGE...

Page 44: ...28 Power Systems Installing your IBM PurePower System ...

Page 45: ......

Page 46: ...IBM Printed in USA ...

Reviews: