Note:
The procedure for installing the cable-management arm involves the assembly of the following
parts:
A
Support arm
B
Cable-management stop bracket
C
Mounting bracket
D
Cable-management arm
E
Extension bracket
The following figure shows the parts of the cable-management arm in relative position to each other
before their assembly.
To install the cable-management arm, complete the following steps:
1.
The cable-management arm must be installed on the right side of the server, when you are facing the
server from the rear, as shown in Figure 12. Connect one end of the support arm
(A)
to the right slide
rail
(1)
so that you can swing the other end of the support arm toward the left side of the rack
(2)
.
2.
Locate the hole at the bottom inside corner of the L-shaped cable-management stop bracket
(B)
.
Position the unattached end of the support arm so that the locking tab on the underside of its tip
aligns with the bracket hole. Insert the tab into the hole
(1)
and turn the bracket
(2)
to secure it to the
Figure 11. Relative positions of cable-management arm parts before assembly
Figure 12. Connecting the support arm
10
Installing the IBM PowerLinux 7R2 (8246-L2D or 8246-L2T)
Summary of Contents for PowerLinux 7R2
Page 1: ...Installing the IBM PowerLinux 7R2 8246 L2D or 8246 L2T GI11 9888 01...
Page 2: ......
Page 3: ...Installing the IBM PowerLinux 7R2 8246 L2D or 8246 L2T GI11 9888 01...
Page 6: ...iv Installing the IBM PowerLinux 7R2 8246 L2D or 8246 L2T...
Page 36: ...24 Installing the IBM PowerLinux 7R2 8246 L2D or 8246 L2T...
Page 57: ......
Page 58: ...Part Number 00L5074 Printed in USA GI11 9888 01 1P P N 00L5074...