IBM Power 720 Express 8202-E4B Installation Manual Download Page 53

Notices

This information was developed for products and services offered in the U.S.A.

The manufacturer may not offer the products, services, or features discussed in this document in other
countries. Consult the manufacturer's representative for information on the products and services
currently available in your area. Any reference to the manufacturer's product, program, or service is not
intended to state or imply that only that product, program, or service may be used. Any functionally
equivalent product, program, or service that does not infringe any intellectual property right of the
manufacturer may be used instead. However, it is the user's responsibility to evaluate and verify the
operation of any product, program, or service.

The manufacturer may have patents or pending patent applications covering subject matter described in
this document. The furnishing of this document does not grant you any license to these patents. You can
send license inquiries, in writing, to the manufacturer.

The following paragraph does not apply to the United Kingdom or any other country where such
provisions are inconsistent with local law:

THIS PUBLICATION IS PROVIDED “AS IS” WITHOUT

WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO,
THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain
transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically
made to the information herein; these changes will be incorporated in new editions of the publication.
The manufacturer may make improvements and/or changes in the product(s) and/or the program(s)
described in this publication at any time without notice.

Any references in this information to websites not owned by the manufacturer are provided for
convenience only and do not in any manner serve as an endorsement of those websites. The materials at
those websites are not part of the materials for this product and use of those websites is at your own risk.

The manufacturer may use or distribute any of the information you supply in any way it believes
appropriate without incurring any obligation to you.

Any performance data contained herein was determined in a controlled environment. Therefore, the
results obtained in other operating environments may vary significantly. Some measurements may have
been made on development-level systems and there is no guarantee that these measurements will be the
same on generally available systems. Furthermore, some measurements may have been estimated through
extrapolation. Actual results may vary. Users of this document should verify the applicable data for their
specific environment.

Information concerning products not produced by this manufacturer was obtained from the suppliers of
those products, their published announcements or other publicly available sources. This manufacturer has
not tested those products and cannot confirm the accuracy of performance, compatibility or any other
claims related to products not produced by this manufacturer. Questions on the capabilities of products
not produced by this manufacturer should be addressed to the suppliers of those products.

All statements regarding the manufacturer's future direction or intent are subject to change or withdrawal
without notice, and represent goals and objectives only.

The manufacturer's prices shown are the manufacturer's suggested retail prices, are current and are
subject to change without notice. Dealer prices may vary.

© Copyright IBM Corp. 2010, 2011

41

Summary of Contents for Power 720 Express 8202-E4B

Page 1: ...Power Systems Installing the IBM Power 720 Express 8202 E4B and IBM Power 740 Express 8205 E6B GI11 9821 02...

Page 2: ......

Page 3: ...Power Systems Installing the IBM Power 720 Express 8202 E4B and IBM Power 740 Express 8205 E6B GI11 9821 02...

Page 4: ...9 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM Power Systems servers that contain the POWER7 processor and to all associated models This edition replaces...

Page 5: ...Cabling the server and accessing Operations Console 25 Cabling the server and accessing the Integrated Virtualization Manager 28 Supporting information for setting up consoles 29 Accessing the ASMI u...

Page 6: ...iv Power Systems Installing the IBM Power 720 Express 8202 E4B and IBM Power 740 Express 8205 E6B...

Page 7: ...e publications package shipped with the product The booklet contains the safety information in your national language with references to the U S English source Before using a U S English publication t...

Page 8: ...d to this product to properly wired outlets v When possible use one hand only to connect or disconnect signal cables v Never turn on any equipment when there is evidence of fire water or structural da...

Page 9: ...e customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock CAUTION v Do not install a unit in a rack where the internal rack ambient temperatures will exceed t...

Page 10: ...of the loaded rack cabinet Refer to the documentation that comes with your rack cabinet for the weight of a loaded rack cabinet v Verify that all door openings are at least 760 x 230 mm 30 x 80 in v E...

Page 11: ...This product might contain one or more of the following devices CD ROM drive DVD ROM drive DVD RAM drive or laser module which are Class 1 laser products Note the following information v Do not remove...

Page 12: ...for NEBS Network Equipment Building System GR 1089 CORE The following comments apply to the IBM servers that have been designated as conforming to NEBS Network Equipment Building System GR 1089 CORE T...

Page 13: ...h an Internet connection http publib boulder ibm com infocenter systems scope hw topic p7hai area3fixeshmc htm Install the server v If you are installing a deskside server see Table 1 v If you are ins...

Page 14: ...ciated information Remove the shipping cover on the back of the system This cover is not needed for system installation Remove the tape that adheres the shipping cover to the system 2 Power Systems In...

Page 15: ...For more information see Enclosures and expansion units http publib boulder ibm com infocenter systems scope hw topic p7ham expansionunit htm Disk drives http publib boulder ibm com infocenter systems...

Page 16: ...mation Install the front cover door The following pictures describe how to install the front cover door To install the rack mounted 8202 E4B and 8205 E6B perform the following high level tasks 4 Power...

Page 17: ...g rails v Cable management arm v Mounting screws v Power supply cables If your shipment contains parts that are not required to complete the installation procedure store those parts until they are req...

Page 18: ...s shipping bracket is not needed for system installation To remove the shipping bracket do the following 1 Remove the screws 2 Pull the power supplies out slightly so that you can remove the shipping...

Page 19: ...systems scope hw topic p7hal p7halkickoff htm and Model 8202 E4B or 8205 E6B PCI adapters http publib boulder ibm com infocenter systems scope hw topic p7hak p8202pcianddiv htm When you are finished c...

Page 20: ...shipping bracket do the following 1 Remove the screws 2 Pull the power supplies out slightly so that you can remove the shipping bracket 3 Re seat the power supplies Note If expansion units are prese...

Page 21: ...face or terminal To cable the system see Cable the system and set up a console interface or terminal Connect power cables and apply power For more information see Completing server setup if you have a...

Page 22: ...10 Power Systems Installing the IBM Power 720 Express 8202 E4B and IBM Power 740 Express 8205 E6B...

Page 23: ...complete the following steps 1 Read the Rack safety notices 2 Plan where to place the units Place the larger and heavier units in the lower part of the rack This system unit is four Electronic Industr...

Page 24: ...Electronic Industries Alliance EIA units high An EIA unit is 44 45 mm 1 75 in in height The rack contains three mounting holes for each EIA unit of height This system therefore is 177 8 mm 7 in high a...

Page 25: ...d hardware components and shows how these components relate to each other Attention To avoid rail failure and potential danger to yourself and to the unit ensure that you have the correct rails and fi...

Page 26: ...t latches into place Note The pin fixtures of the slide rails support either round hole or square hole rack models as shown 3 Pull the slide rail forward and insert the two pins 1 in Figure 5 on page...

Page 27: ...w 7 Pull the slide rails forward 1 in Figure 7 on page 16 until they click twice into place Carefully lift the server and tilt it into position over the slide rails so that the rear nail heads 2 on th...

Page 28: ...they are fully seated and latched 10 Next you must install the cable management arm For more information see Installing the cable management arm Installing the cable management arm You might need to i...

Page 29: ...shows it being installed on the right side Connect one end of the support arm 1 to the right slide rail so that you can swing the other end of the support arm 2 toward the left side of the rack 2 Loc...

Page 30: ...acket 2 into the left slide rail 4 Pull out the mounting bracket pin 1 and slide the mounting bracket 2 into the right slide rail Push the bracket into the slide rail until the spring loaded pin snaps...

Page 31: ...slide rail Push the tab until it snaps into place 6 Route the power cords and other cables including keyboard monitor and mouse cables if required on the cable management arm 1 Attach all cables to t...

Page 32: ...ntion bracket re seat the power supply 3 Plug the power cord into the power supply Note If the system is equipped with two power supplies each must have its own power cord plugged in 4 Plug the system...

Page 33: ...II terminal AIX Linux or VIOS Yes for VIOS no for AIX and Linux Serial cable equipped with a null modem Cabling the server with an ASCII terminal on page 23 Hardware Management Console AIX IBM i Linux...

Page 34: ...ion 50ADxxx AC input and power supply related errors 1 Verify that line cords are plugged in correctly in the draw power distribution unit PDU if applicable battery backup unit BBU if applicable and i...

Page 35: ...X Linux or VIOS operating systems From the ASCII terminal you can access the Advanced System Management Interface ASMI to perform additional installation tasks The ASCII terminal is connected to the s...

Page 36: ...gical partitions and the use of capacity on demand Using service applications the HMC communicates with managed systems to detect consolidate and forward information to IBM service for analysis Before...

Page 37: ...ress that will be assigned to the server s LAN console adapter for use by the console including information about the IP subnet mask and default gateway 3 Select a unique host name and register the ho...

Page 38: ...2 Set the subnet mask to the opcon LAN adapter subnet 3 Set the default gateway to the opcon LAN adapter primary router or gateway address This address is the same address as the IP address 4 Disable...

Page 39: ...er on the server by completing the following steps a Set the manual IPL by completing the following steps 1 Locate the server s control panel Look for the blue tab on the front of the server Push it t...

Page 40: ...ty in ASMI v Using the Web based ASMI change the following settings as appropriate for the type of partition on which you are installing the Integrated Virtualization Manager For an AIX or Linux parti...

Page 41: ...ng steps a Connect your power cord or cords to the server b Plug the power cord or cords into the power source c Wait for the control panel to display 01 A series of progress codes are shown before 01...

Page 42: ...5 255 255 0 169 254 3 146 169 254 3 140 5 Set the IP address on your PC or notebook using the values from the table For details see Setting the IP address on your PC or notebook 6 To access the ASMI u...

Page 43: ...ASMI using a Web Browser task 8 Click OK on the Local Area Connection Properties window It is not necessary to restart your PC Linux To set the IP address within the Linux operating system do the foll...

Page 44: ...lly change if an Ethernet cable that is attached to a network is connected to that port and the system is turned on If you are unable to access the ASMI using a network connection you must perform one...

Page 45: ...d instructions about how to perform these tasks see Completing server setup if you do not have an HMC on page 36 Completing server setup if you have an SDMC You must perform these tasks to complete se...

Page 46: ...is is a new host or if this host does not yet have virtual servers created do the following to prepare this host for creating virtual servers a Configure the system with a single full system virtual s...

Page 47: ...elect Updates Firmware information is displayed in the contents area 5 Compare your installed firmware level with available firmware levels If required update your firmware levels a Compare your insta...

Page 48: ...MI For more information see Accessing the ASMI without an HMC http publib boulder ibm com infocenter systems scope hw topic p7hby connect_asmi htm b On the ASMI Welcome pane note the existing level of...

Page 49: ...stems scope hw topic p7ha5 fix_firm_no_hmc_aix htm v If you are using IBM i use the IBM i PTF installation functions to install the server firmware fixes v If you are using VIOS see Updating the Virtu...

Page 50: ...38 Power Systems Installing the IBM Power 720 Express 8202 E4B and IBM Power 740 Express 8205 E6B...

Page 51: ...plied This system requires 220 volts The following table describes system reference codes that you might encounter during installation Table 10 Common installation system reference codes SRCs System r...

Page 52: ...reference code Error description Recovery steps B1A38B24 Network configuration An invalid network configuration was entered by the user Often a duplicate IP address was entered 40 Power Systems Instal...

Page 53: ...or changes in the product s and or the program s described in this publication at any time without notice Any references in this information to websites not owned by the manufacturer are provided for...

Page 54: ...here is independent data verification before relying on such data in sensitive or critical operations Users should periodically check the manufacturer s support websites for updated information and fi...

Page 55: ...2 this device must accept any interference received including interference that may cause undesired operation Industry Canada Compliance Statement This Class A digital apparatus complies with Canadia...

Page 56: ...n JEITA Confirmed Harmonics Guideline products less than or equal to 20 A per phase Japanese Electronics and Information Technology Industries Association JEITA Confirmed Harmonics Guideline with Modi...

Page 57: ...Vertr glichkeit Dieses Produkt entspricht den Schutzanforderungen der EU Richtlinie 2004 108 EG zur Angleichung der Rechtsvorschriften ber die elektromagnetische Vertr glichkeit in den EU Mitgliedsst...

Page 58: ...f r die Einhaltung der EMV Vorschriften ist der Hersteller International Business Machines Corp New Orchard Road Armonk New York 10504 Tel 914 499 1900 Der verantwortliche Ansprechpartner des Herstell...

Page 59: ...complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received inc...

Page 60: ...ies Association JEITA Confirmed Harmonics Guideline with Modifications products greater than 20 A per phase IBM Taiwan Contact Information Electromagnetic Interference EMI Statement Korea Germany Comp...

Page 61: ...International Business Machines Corp New Orchard Road Armonk New York 10504 Tel 914 499 1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist IBM Deutschland GmbH Technical Regulatio...

Page 62: ...in full compliance with all applicable laws and regulations including all United States export laws and regulations IBM MAKES NO GUARANTEE ABOUT THE CONTENT OF THESE PUBLICATIONS THE PUBLICATIONS ARE...

Page 63: ......

Page 64: ...Part Number 16R3036 Printed in USA GI11 9821 02 1P P N 16R3036...

Reviews: