![IBM PC 100 Technical Manual Download Page 21](http://html1.mh-extra.com/html/ibm/pc-100/pc-100_technical-manual_4227583021.webp)
Chapter 1. System Description
Connector Description
The power supply has four, 4-pin connectors for internal devices. The total power used by the connectors
must not exceed the amount shown in Figure 10 on page 12. Signal and pin assignments are shown on
page 20.
Physical Specifications
The following figure shows the physical specifications for the PC 100 and PC 300.
Figure 11. Physical Specifications
Size
Width
440 mm (17.32 in.)
Depth
420 mm (16.53 in.)
Height
102 mm (4.00 in.)
Weight
Minimum configuration
8.0 kg (17.61 lb)
Maximum configuration (fully populated with typical options)
10.0 kg (22.0 lb)
Cables
Power cable
1.8 m (6 ft)
Keyboard cable
Approx. 2 m (10 ft)
Air Temperature
System on
10.0 to 32.0°C (50 to 90°F)
System off
10.0 to 43.0°C (50 to 110°F)
Humidity
System on
8% to 80%
System off
8% to 80%
Maximum Altitude
ñ
2133.6 m (7000 ft)
Heat Output
Minimum configuration
20 W (68.57 Btu per hour)
Maximum configuration
ò
210 W (719.25 Btu per hour)
Electrical
Input voltage (range is switch selected; sine wave input is required)
Low range
110 (min) to 127 (max) V ac
High range
200 (min) to 240 (max) V ac
Frequency
50
±
3 Hz or 60
±
3 Hz
Input, in kilovolt-ampere (kVA)
Minimum configuration
0.08 kVA
Maximum configuration
0.30 kVA
Electromagnetic Compatibility
FCC Class B
ñ
This is the maximum altitude at which the specified air temperatures apply. At higher altitudes, the maximum air
temperatures are lower than those specified.
ò
Based on the 145-watt maximum capacity of the system power supply.
Chapter 1. System Description
13
Summary of Contents for PC 100
Page 1: ...IBM Technical Information Manual PC 100 Type 6260 and PC 300 Type 6560 S78H 5142 00...
Page 2: ......
Page 3: ...IBM Technical Information Manual PC 100 Type 6260 and PC 300 Type 6560 S78H 5142 00...
Page 57: ......
Page 58: ...IBM Part Number 78H5142 Printed in U S A 78H5142 S78H 5142...