51
Table 2-1 BIOS Error Codes, Messages, and Beeps List
BIOS Error Codes, Messages,
beeps
Action/FRU
NOTE:
To diagnose a problem, first find the BIOS error messages, codes, or beeps in left column. If
directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure
is indicated, the first Action/FRU listed in right column is the most likely cause.
201
Memory test failure.
Insert the memory modules in the DIMM sockets properly, and then
reboot the system.
Memory module. See the “Step 005” of ”Memory” on page 64 to
replace memory module.
System board.
301
Keyboard error or no keyboard
present.
Make sure the keyboard is connected properly and are set correctly in
BIOS Setup.
System board.
662
FLOPPY DISK(S) failure (80)
Unable to reset floppy subsystem.
662
FLOPPY DISK(S) failure (40)
Floppy Type mismatch.
1701
Hard disk(s) Diagnosis failure
Make sure the hard disks are set correctly in BIOS setup.
Hard disk drive cable/connection.
Hard disk drive.
System board.
1762
Primary master IDE has changed
Primary slave IDE has changed
Secondary master IDE has
changed
Secondary slave IDE has
changed
Make sure that the System Boot Drive parameter in the Startup
Options of BIOS Setup is not set to [Drive A only].
Load default settings in Setup.
Insert a system diskette into diskette drive and reboot system.
Make sure the diskette drive configuration setting in BIOS Setup is
correct.
Hard disk drive power.
Diskette drive.
System board.
1780
Primary master hard disk failure
1781
Primary slave hard disk failure
A warning message to indicate there has been a change of IDE
Primary (Secondary) Channel Master (Slave) device.
Load default settings in Setup.
Check IDE drive jumper. See “3.5-In. Hard Disk Drive Jumper
Locations” on page 107.
IDE drive power.
IDE drive cable/connection.
IDE drive.
1782
Secondary master hard disk
failure
1783
Secondary slave hard disk failure
A warning message to indicate there has been a change of IDE
Primary (Secondary) Channel Master (Slave) device.
Load default settings in Setup.
Check IDE drive jumper. See ”3.5-In. Hard Disk Drive Jumper
Locations” on page107.
IDE drive power.
IDE drive cable/connection.
IDE drive.
8602
Mouse error on no Mouse present
Make sure the Mouse is connected properly and is set up correctly in
BIOS Setup.
Mouse.
System board.
SYSTEM HALTED, (
CTRL-ALT-
DEL
) TO REBOOT…
Indicates the present boot attempt has been aborted and the system
must be rebooted. Press and hold down the
CTRL
and
ALT
key and
DEL
.
Hard Disk(s) failure (80)
Hard Disk Drive reset failed.
Summary of Contents for NetVista
Page 10: ...10...
Page 11: ...11...