Figure 73. Connectors for the upper cable management arm
1
Inner connector on the upper CMA
2
Connector base on inner rail member
3
Outer connector on the upper CMA
4
Connector base on outer rail member
5
Support rail connector on the upper CMA
6
Connector base on outer rail member
1. Press the latch on the connector base on the upper CMA assembly (
5
2. Pull the connector to remove it from the connector base on the right support rail (
6
3. Press the latch on the outer connector of the upper CMA assembly (
3
4. Remove the outer connector from the inner member of the left support rail (
4
78).
5. Remove the inner connector of the upper CMA assembly (
1
) from the inner member of the left
support rail (
2
), as shown in Figure 73 on page 78.
Remove the lower CMA assembly
Note: The procedure for removing the lower CMA assembly is the same as the procedure to remove the
upper CMA assembly. However, the connector locations are reversed. For example, the connector base of
the upper CMA (
5
in Figure 73 on page 78) connects to the right rail. The connector base of the lower
CMA (
11
in Figure 74 on page 79) attaches to the left rail.
78 IBM Cloud Object Storage System
™
Version 3.15.6: J15 Appliance Manual
Summary of Contents for J15
Page 1: ...IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual IBM...
Page 10: ...x...
Page 12: ...xii...
Page 24: ...xxiv IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual...
Page 32: ...4 IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual...
Page 140: ...112 IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual...
Page 141: ......