Press
the
Unload
Button
to
stop
the
diagnostic
and
exit
maintenance
mode.
Pressing
the
Unload
Button
once
will
abort
the
test
at
the
end
of
the
current
test
loop.
Pressing
the
Unload
Button
twice
will
abort
the
test
immediately.
Wait
for
the
drive
to
rewind
the
tape
and
unload
the
cartridge.
Attention:
When
you
perform
this
test,
data
on
the
suspect
tape
will
be
overwritten.
Note:
If
you
inserted
an
invalid
tape
cartridge
(e.g.
Gen1
or
WORM
media),
error
code
7
appears
in
the
SCD.
If
you
inserted
a
write-protected
cartridge,
or
the
media
has
read-only
compatibility
(e.g.,
Gen2
media),
error
code
P
appears
in
the
SCD.
In
either
case,
the
tape
drive
unloads
the
cartridge
and
exits
Maintenance
Mode
after
the
cartridge
is
removed.
1.
Place
the
drive
in
Maintenance
Mode.
For
instructions,
see
2.
Press
the
Unload
Button
once
per
second
until
E
appears
in
the
SCD.
(If
you
cycle
past
the
desired
code,
press
the
Unload
Button
once
per
second
until
the
code
reappears.)
3.
Press
and
hold
the
Unload
Button
for
three
or
more
seconds,
then
release
it
to
select
the
function.
The
SCD
changes
to
a
flashing
C
requesting
a
cartridge.
4.
Ensure
that
the
write-protect
switch
on
the
cartridge
is
off,
then
insert
the
cartridge
(or
the
tape
drive
exits
maintenance
mode).
The
SCD
changes
to
flashing
E
.
The
tape
drive
runs
the
tests.
v
If
no
error
is
detected,
the
diagnostic
will
loop
and
begin
again.
To
stop
the
loop,
press
the
Unload
Button
for
one
second
and
release.
When
the
loop
ends,
0
temporarily
appears
in
the
SCD.
v
If
an
error
is
detected,
the
Status
Light
flashes
amber
and
the
drive
posts
an
error
code
to
the
SCD.
To
determine
the
error,
locate
the
code
in
To
clear
the
error
either
turn
the
power
off
and
then
on
again,
or
reboot
the
drive
by
pressing
and
holding
the
Unload
Button
for
10
seconds.
Function
Code
F:
Write
Performance
Test
Approximate
Run
Time
=
5
minutes
per
loop
Total
Number
of
Loops
=
10
Function
Code
F
performs
tests
to
ensure
that
the
drive
can
read
from
and
write
to
tape.
Press
the
Unload
Button
to
stop
the
diagnostic
and
exit
maintenance
mode.
Pressing
the
Unload
Button
once
will
abort
the
test
at
the
end
of
the
current
test
loop.
Pressing
the
Unload
Button
twice
will
abort
the
test
immediately.
Wait
for
the
drive
to
rewind
the
tape
and
unload
the
cartridge.
Chapter
3.
Operating
3-17
Summary of Contents for H4S
Page 2: ......
Page 6: ...iv TS2240 Tape Drive Setup Operator and Service Manual ...
Page 10: ...viii TS2240 Tape Drive Setup Operator and Service Manual ...
Page 12: ...x TS2240 Tape Drive Setup Operator and Service Manual ...
Page 14: ...xii TS2240 Tape Drive Setup Operator and Service Manual ...
Page 38: ...2 8 TS2240 Tape Drive Setup Operator and Service Manual ...
Page 76: ...5 6 TS2240 Tape Drive Setup Operator and Service Manual ...
Page 84: ...B 2 TS2240 Tape Drive Setup Operator and Service Manual ...
Page 92: ...C 8 TS2240 Tape Drive Setup Operator and Service Manual ...
Page 118: ...F 6 TS2240 Tape Drive Setup Operator and Service Manual ...
Page 136: ...X 4 TS2240 Tape Drive Setup Operator and Service Manual ...
Page 139: ......
Page 140: ... Part Number 45E1880 Printed in USA GC27 2151 00 1P P N 45E1880 ...