Support for up to 64 virtual drives, up to 128 drive groups, up to 16 virtual drives per one drive group, 

and up to 32 physical drives per one drive group

Support for logical unit number (LUN) sizes up to 64 TB

Configurable stripe size up to 1 MB

Compliant with Disk Data Format (DDF) configuration on disk (COD)

S.M.A.R.T. support

Managed through the IMMv2 management processor on the compute node and with the MegaRAID 

Storage Manager management software

Architecture

Figure 2 shows the architecture of the Storage Expansion Node when connected to a compute node.

Figure 2. Architecture of the Storage Expansion Node

The Expansion Node connects to a standard-width compute node using the interposer cable, which plugs 

into the expansion connector on the compute node. This link forms a PCIe 3.0 x8 connection between 
Processor 2 on the compute node and the LSI RAID controller in the Expansion Node. The result is that 
the compute node sees the disks in the expansion node as locally attached. Management of the Storage 
Expansion Node is via the IMM2 located on the compute node.

Note: The expansion connector in the x220 and x240 compute nodes is routed through processor 2. 

Therefore, processor 2 must be installed in the compute node.

Summary of Contents for Flex System 68Y8588

Page 1: ...S infrastructure video survellance and streaming solutions Figure 1 shows the IBM Flex System Storage Expansion Node attached to an IBM Flex System x240 Compute Node Figure 1 IBM Flex System Storage E...

Page 2: ...both processors be installed in the x220 and x240 Features The System Expansion Node has the following features Connects directly to supported compute nodes via a PCIe 3 0 interface to the compute no...

Page 3: ...re of the Storage Expansion Node when connected to a compute node Figure 2 Architecture of the Storage Expansion Node The Expansion Node connects to a standard width compute node using the interposer...

Page 4: ...n Node with drive tray part way extended The following table lists the hard disk drives HDDs and solid state drives SSDs supported within the Storage Expansion Node Both SSDs and HDDs can be installed...

Page 5: ...IBM Flex System 1 90Y4412 A2Y2 ServeRAID M5100 Series Performance Accelerator for IBM Flex System 1 The cache upgrades are mutually exclusive FoD upgrades for ServeRAID are system wide If you have th...

Page 6: ...DD arrays with only an incremental investment in solid state drive SSD technology The feature enables the SSDs to be configured as a dedicated cache to help maximize the I O performance for transactio...

Page 7: ...hreshold Close door immediately to avoid drive damage In addition to the lights described in the previous table there are LEDs locally on each of the drive trays These lights can be observed when the...

Page 8: ...ft Maximum rate of temperature change 5 C hr 41 F hr Regulatory compliance The unit conforms to the following standards ASHRAE Class A3 FCC Verified to comply with Part 15 of the FCC Rules Class A Can...

Page 9: ...bm com infocenter flexsys information index jsp IBM ServerProven hardware compatibility page for IBM Flex System http www ibm com systems info x86servers serverproven compat us IBM Flex System x240 Co...

Page 10: ...f the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any...

Page 11: ...arks of International Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms are marked on their first occurrence in this information with the...