Figure 5. LEDs on the front of the Storage Expansion Node

Table 5 identifies the meanings of the LEDs.

Table 5. External LED status table

LED

Color

Meaning

Activity light
(each drive 

bay)

Green

Blinks with Activity, displaying drive number. 

Fault/Locate

Amber

Solid: Indicates a fault on one of the drives

Blink: One of the drives is set to “identify”

Tray Open

Amber

Flash/beep 15 sec interval: Drawer is not fully closed. 

Flash/beep 5 sec interval: Drawer has been opened to long, close drawer immediatly

Flash/beep .25 sec interval: Expansion node has reached thermal threshold. Close 

door immediately to avoid drive damage.

In addition to the lights described in the previous table, there are LEDs locally on each of the drive trays. 

These lights can be observed when the drive tray is extended and the unit is operational. A green LED 
indicates disk activity and an amber LED indicates a drive fault. 

With the Storage Expansion Node removed from the Flex System chassis and its cover removed, there 

are additional LEDs visible. If there is a fault detected then the relevant LED will light:

Flash/RAID adapter: RAID Cache card fault.

Control panel: LED panel card not present

Temperature: A temperature event has occured

Storage expansion: Fault on the storage expansion unit

Light path: Verify that the light path diagnostic function, including the battery, is operating properly

Summary of Contents for Flex System 68Y8588

Page 1: ...S infrastructure video survellance and streaming solutions Figure 1 shows the IBM Flex System Storage Expansion Node attached to an IBM Flex System x240 Compute Node Figure 1 IBM Flex System Storage E...

Page 2: ...both processors be installed in the x220 and x240 Features The System Expansion Node has the following features Connects directly to supported compute nodes via a PCIe 3 0 interface to the compute no...

Page 3: ...re of the Storage Expansion Node when connected to a compute node Figure 2 Architecture of the Storage Expansion Node The Expansion Node connects to a standard width compute node using the interposer...

Page 4: ...n Node with drive tray part way extended The following table lists the hard disk drives HDDs and solid state drives SSDs supported within the Storage Expansion Node Both SSDs and HDDs can be installed...

Page 5: ...IBM Flex System 1 90Y4412 A2Y2 ServeRAID M5100 Series Performance Accelerator for IBM Flex System 1 The cache upgrades are mutually exclusive FoD upgrades for ServeRAID are system wide If you have th...

Page 6: ...DD arrays with only an incremental investment in solid state drive SSD technology The feature enables the SSDs to be configured as a dedicated cache to help maximize the I O performance for transactio...

Page 7: ...hreshold Close door immediately to avoid drive damage In addition to the lights described in the previous table there are LEDs locally on each of the drive trays These lights can be observed when the...

Page 8: ...ft Maximum rate of temperature change 5 C hr 41 F hr Regulatory compliance The unit conforms to the following standards ASHRAE Class A3 FCC Verified to comply with Part 15 of the FCC Rules Class A Can...

Page 9: ...bm com infocenter flexsys information index jsp IBM ServerProven hardware compatibility page for IBM Flex System http www ibm com systems info x86servers serverproven compat us IBM Flex System x240 Co...

Page 10: ...f the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any...

Page 11: ...arks of International Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms are marked on their first occurrence in this information with the...

Reviews: