background image

IBM Flex System FC5022 16Gb SAN Scalable Switches

6

mode utilizes N_Port ID Virtualization (NPIV) switch standards to present physical and virtual servers
directly to the core of SAN fabrics. This makes it transparent to the SAN fabric, greatly reducing 
management of the network edge. The IBM SAN Scalable Switch in Access Gateway mode can 
connect servers to NPIV-enabled SAN fabrics, including IBM, Brocade B-Series, other vendor 
Brocade SAN fabrics, or Cisco SAN fabrics.

Maximizing investments

To help optimize technology investments, IBM offers a single point of serviceability backed by 

industry-renowned education, support, and training. In addition, the IBM 16/8 Gbps SAN Scalable 
Switch is in the ServerProven® program, ensuring compatibility among a variety of IBM and partner 
products. IBM recognizes that customers deserve the most innovative, expert integrated systems 
solutions.

Features and specifications

The FC5022 16 Gb Switches have the following features and specifications:

Internal ports

28 internal full-duplex 16/8 Gb FC ports

Internal ports operate as F_ports (fabric ports) in native mode or in access gateway mode

Two internal full-duplex 1 GbE ports connected to the chassis management module

Support for the 2-port and 4-port FC adapter cards

External ports

20 external ports for 16 Gb SFP+ or 8 Gb SFP+ transceivers supporting 4 Gb, 8 Gb, and 16 Gb 

port speeds (supported SFP+ modules are listed in Table 2). Ports are activated with the Dynamic 
Ports on Demand feature.

External ports can operate as F_ports (fabric ports) or E_ports (expansion ports) in native mode 

or as N_ports NPIV (node ports) in Access Gateway mode

One external 1 GbE port (1000BASE-T) with RJ-45 connector for switch configuration and 

management

One RS-232 serial port (mini-USB connector) that provides an additional means to configure the 

switch module

Access Gateway mode (N_Port ID Virtualization - NPIV) support

Power-on self-test diagnostics and status reporting

Inter-Switch Link (ISL) Trunking (licensable or included with the 24-port ESB model), which allows up 

to eight ports (at 16, 8, or 4 Gbps speeds) to combine to form a single, logical ISL with a speed of up 
to 128 Gbps (256 Gbps full duplex) for optimal bandwidth utilization, automatic path failover, and load 
balancing

Fabric OS (FOS) version 7.0.x or higher, which delivers distributed intelligence throughout the 

network and enables a wide range of value-added applications, such as Advanced Web Tools and 
Advanced Fabric Services (on certain models)

Supports  up to 768 Gbps I/O bandwidth

420 million frames switch per second, 0.7 microseconds latency

8192 buffers for up to 3750 km extended distance at 4 Gbps FC (Extended Fabrics license required)

In-flight 64 Gbps FC compression and decompression support on up to two external ports (no license 

required)

Summary of Contents for FC5022

Page 1: ...ue differentiation in the market including Increased server density The 28 internal FC ports allow up to 28 Information ITEs in a single chassis which lowers the average server cost of the solution Gr...

Page 2: ...ex System FC5022 16 Gb Fabric Watch Upgrade 00Y3320 A3HN ESW3 IBM Flex System FC5022 16 Gb ISL Trunking Upgrade 00Y3322 A3HP ESW4 The part numbers for the switches include the following items One IBM...

Page 3: ...on by model for IBM Flex System FC5022 switches Table 3 Feature comparison by model Feature 24 port 16 Gb ESB SAN switch 24 port 16 Gb SAN switch 16 Gb SAN switch Number of licensed ports 24 24 12 Num...

Page 4: ...bre Channel FC ports After all port licenses have been assigned you can manually move those licenses from one port to another Because this is dynamic no defined ports are reserved except ports 0 and 2...

Page 5: ...the only switch that provides up to 28 internal server facing FC ports which allows the Flex Chassis to scale to 28 server ITEs in a single chassis when using double density half width ITEs that lowe...

Page 6: ...for 16 Gb SFP or 8 Gb SFP transceivers supporting 4 Gb 8 Gb and 16 Gb port speeds supported SFP modules are listed in Table 2 Ports are activated with the Dynamic Ports on Demand feature External port...

Page 7: ...ng functionality contained within the Ethernet Control MIB II RFC1213 MIB UUID put into MIB structure End to end optics and link validation Ability to send switch events and syslogs to the IBM Chassis...

Page 8: ...FC standards FC AL 2 INCITS 332 1999 FC GS 5 ANSI INCITS 427 includes the following FC GS 4 ANSI INCITS 387 2004 FC IFR INCITS 1745 D revision 1 03 under development FC SW 4 INCITS 418 2006 includes...

Page 9: ...route to two switch bays for redundancy and performance Figure 2 Location of the switch bays in the IBM Flex System Enterprise Chassis The connections between the 2 port adapters that are installed i...

Page 10: ...must be installed in a corresponding slot of the compute node slot A1 when switches are installed in bays 1 and 2 or slot A2 when switches are in bays 3 and 4 With compute nodes that have an integrat...

Page 11: ...Module bay 2 Port 3 Module bay 1 Slot 3 full wide compute nodes only Port 4 Module bay 2 Port 1 Module bay 3 Port 2 Module bay 4 Port 3 Module bay 3 Slot 4 full wide compute nodes only Port 4 Module b...

Page 12: ...Y2379 A3HU A3HU Yes IBM Flex System FC5052 2 port 16Gb FC Adapter 95Y2386 EC23 A45R Yes IBM Flex System FC5054 4 port 16Gb FC Adapter 95Y2391 EC2E A45S Yes IBM Flex System FC5172 2 port 16Gb FC Adapte...

Page 13: ...the switch physically by illuminating via the management software The Error LED switch module error indicates that the switch module has failed the POST or detected an operational fault One mini USB R...

Page 14: ...5 km LC Management ports External 1 GbE management port UTP Category 5 5E and 6 up to 100 meters RJ 45 External RS 232 management port DB 9 to mini USB or RJ 45 to mini USB console cable comes with op...

Page 15: ...eports and certificates per EN60950 1 2001 IEC60950 1 2001 Canada CSA C22 2 No 950 or 60950 Germany TUV VDE IEC 950 EN 60950 TUV component report IEC60950 CB Report and Certificate FCC Title 47 CFR Pa...

Page 16: ...dapters installed in compute nodes Table 10 shows the components used when connecting the 16 Gb FC adapters to the 16 Gb FC switches Table 10 Components used when connecting the 16 Gb FC adapters to t...

Page 17: ...ssi cgi bin ssialias infotype dd subtype ca htmlfid 897 ENUS112 053 IBM US Announcement Letter for the 16Gb 24 port SAN switch http ibm com common ssi cgi bin ssialias infotype dd subtype ca htmlfid...

Page 18: ...part of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurri...

Page 19: ...s of International Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms are marked on their first occurrence in this information with the ap...

Reviews: