Chapter
7.
Administering
the
Cluster
1350
This
chapter
includes
information
about:
v
accessing
the
cluster
from
a
remote
location
v
accessing
each
node
before
the
operating
system
is
installed
v
shutting
down
the
system
components
v
finding
information
about
a
lights
out
or
brown
out
event
For
more
information
about
monitoring,
remote
control,
set-up,
and
technical
references,
see:
http://www.ibm.com/servers/eserver/clusters/library/linux.html
Using
the
remote
power
command
Using
the
command
rpower
starts
and
resets
hardware,
powers
hardware
on
and
off,
and
queries
the
node
power
state.
The
syntax
is:
rpower
[
-a
]
[
-h
]
[
-n
host
[,
host...
]]
[
-N
Node_group
[,
Node_group...
]]
[
-v
]
on
|
off
|
reboot
|
query
|
resetsp
Remote
console
The
remote
console
function
uses
the
serial
ports
of
xSeries
335
servers
and
terminal
servers.
The
serial
ports
provide
remote
access
to
nodes
before
the
operating
system
is
installed
or
when
network
access
to
the
servers
is
unavailable
or
has
failed.
The
terminal
servers
must
be
included
to
enable
the
remote
console
function.
Each
rack
in
the
configuration
includes
one
or
two
terminal
servers
to
connect
each
node
in
the
rack
through
a
DB9
to
RH45
serial
cable.
The
terminal
servers
are
LAN
connected
to
the
Management
VLAN.
The
remote
console
function
is
accessed
through
the
rconsole
command.
This
command
opens
a
remote
console
session
for
any
cluster
node.
The
syntax
is:
rconsole
[
-a
]
[
-h
]
[
-n
host
[
,host...
]]
[
-N
Node_group
[,
Node_group...
]
Shutting
down
the
system
components
Because
the
operating
system
is
installed
on
each
node,
the
procedures
to
shut
down
the
nodes
are
relatively
simple.
Complete
the
following
steps
to
shut
down
the
cluster
nodes:
1.
Log
off
the
cluster
nodes
and
the
storage
nodes.
2.
To
turn
the
cluster
nodes
off
with
Cluster
System
Management
(CSM)
installed
on
the
management
node,
at
the
command
prompt,
type
rpower
off
-A
Note:
If
CSM
is
not
installed
on
the
management
node,
turn
off
the
power
switch
for
each
individual
cluster
node.
3.
Turn
off
the
power
for
the
following
devices:
v
storage
nodes
v
management
node
v
storage
controllers
v
storage
expansion
units
4.
Turn
off
the
power
switch
for
the
power
distribution
units
or
unplug,
from
the
power
distribution
unit,
the
devices
that
have
no
power
switch.
©
Copyright
IBM
Corp.
2004
35
Summary of Contents for eserver Cluster 1350
Page 1: ...IBM Eserver Cluster 1350 Installation and Service Guide ERserver...
Page 2: ......
Page 3: ...IBM Eserver Cluster 1350 Installation and Service Guide ERserver...
Page 26: ...10 IBM Eserver Cluster 1350 Installation and Service Guide...
Page 82: ...66 IBM Eserver Cluster 1350 Installation and Service Guide...
Page 86: ...70 IBM Eserver Cluster 1350 Installation and Service Guide...
Page 88: ...72 IBM Eserver Cluster 1350 Installation and Service Guide...
Page 90: ...74 IBM Eserver Cluster 1350 Installation and Service Guide...
Page 94: ...78 IBM Eserver Cluster 1350 Installation and Service Guide...
Page 98: ...82 IBM Eserver Cluster 1350 Installation and Service Guide...
Page 104: ...88 IBM Eserver Cluster 1350 Installation and Service Guide...
Page 114: ...98 IBM Eserver Cluster 1350 Installation and Service Guide...
Page 120: ...104 IBM Eserver Cluster 1350 Installation and Service Guide...
Page 121: ......
Page 122: ...Part Number 25K8407 Printed in USA 1P P N 25K8407...