background image

IBM Flex System Fabric EN4093 and EN4093R 10 Gb
Scalable Switch

User's Guide

Summary of Contents for EN4093R

Page 1: ...IBM Flex System Fabric EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...

Page 2: ......

Page 3: ...IBM Flex System Fabric EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...

Page 4: ...ion and Environmental Notices and User Guide documents on the IBM Notices for Network Devices CD and the Warranty Information document that comes with the product Fourth Edition October 2013 Copyright...

Page 5: ...nsole cable 13 Connecting the SFP and QSFP module cable 13 Disconnecting the SFP and QSFP module cable 13 Connecting the RJ 45 cable 14 Disconnecting the RJ 45 cable 14 Locating the information panels...

Page 6: ...Canada Class A emission compliance statement 41 Avis de conformit la r glementation d Industrie Canada 41 Australia and New Zealand Class A statement 41 European Union EMC Directive conformance state...

Page 7: ...tteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare que...

Page 8: ...versions of the caution or danger statement in the Safety Information document For example if a caution statement is labeled Statement 1 translations for that caution statement are in the Safety Info...

Page 9: ...nt when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructed ot...

Page 10: ...ls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products contain an embedded Class 3A or Class 3B laser...

Page 11: ...ion about the switch at http www ibm com supportportal Notes 1 The illustrations in this document might differ slightly from your hardware 2 The screens that are described or referenced in this docume...

Page 12: ...tremely hazardous procedure step or situation Features and specifications For detailed information about the switch hardware and firmware features specifications and standards see the switch Applicati...

Page 13: ...ute node with which you want to communicate To enable the switch to communicate with a compute node at least one switch must be installed in the IBM Flex System chassis For details about network adapt...

Page 14: ...ps The external ports can operate at 1 Gbps or 10 Gbps depending on the SFP module type Before installing the switch module Locate and record information about the switch module in the following table...

Page 15: ...he IBM Flex System chassis and operating system support hot swap capability you can remove or install the component while the IBM Flex System chassis is running Orange can also indicate touch points o...

Page 16: ...e in for at least 2 seconds This drains static electricity from the package and from your body v Remove the device from its package and install it directly into the IBM Flex System chassis without set...

Page 17: ...tatic protective package 7 Make sure that the release levers on the switch are in the open position perpendicular to the switch 8 Slide the switch into the applicable I O bay until it stops 9 Push the...

Page 18: ...the switch complete the following steps 1 Read the safety information that begins on page v and Installation guidelines on page 5 2 Disconnect any cables from the switch that you are removing Removin...

Page 19: ...s to optical signals For additional information about the location of the switch the network interface requirements and expansion options see the documentation for your IBM Flex System chassis Notes 1...

Page 20: ...kan 1 Laserlaite Appareil A Laser de Classe 1 Installing the SFP module The SFP module provides two fiber optic cable connectors for connecting to external ports To install an SFP module complete the...

Page 21: ...Insert the module into the port until it clicks into place Use minimal pressure when you insert the module into the port Do not use excessive force when you insert the module you can damage the module...

Page 22: ...lightly from your hardware Connecting the serial console cable To connect the serial console cable to the switch connect the serial cable to the RS 232 serial console port of the switch and the other...

Page 23: ...ck v Do not overtighten the cable straps or bend the cables to a radius of less than 38 mm 1 5 in v Do not put excess weight on the cable at the connection point Make sure that the cable is well suppo...

Page 24: ...switch module connector Locating the information panels LEDs and external ports This section describes the information panels and LEDs on the switch and identifies the external ports on the informatio...

Page 25: ...tch module information panel contains the following components v LEDs that display the following information The status of the switch OK Identify and Error The status of the external connections to th...

Page 26: ...Notes 1 A yellow LED on the IBM Flex System chassis is lit when a system error or event has occurred To identify the error or event check the IBM Flex System management module event log or the switch...

Page 27: ...BM Flex System chassis is also lit v When this LED is not lit and the green LED is lit it indicates that the switch is working correctly If the green LED is also not lit it indicates that the switch i...

Page 28: ...18 EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...

Page 29: ...ule This mode can be enabled only through the Chassis Management Module configuration interface When this mode is enabled the external SFP and QSFP ports support both management and data traffic This...

Page 30: ...ise stated references to the management module apply only to the IBM Flex System Chassis Management Module which is the only type of management module that supports the switch v Throughout this docume...

Page 31: ...lication see Accessing the switch through the browser based interface on page 23 for additional information v If your system application requires that you use the SSHv2 Telnet client software see Acce...

Page 32: ...ctions describe how to use the SSHv2 Telnet interface to access the switch Connecting to the switch If you know the IP address for the switch and you have an existing network connection you can use th...

Page 33: ...password PASSW0RD where the sixth character is the number zero not the letter O The serial port is compatible with the standard 16550 Universal Asynchronous Receiver Transmitter UART protocol The RS...

Page 34: ...odule to factory defaults the original configuration is restored For more information about configuring and managing the switch see the Command Reference for the switch Logging in to the switch The sw...

Page 35: ...ine the level of the firmware that is installed complete the following steps 1 Log on to the IBM Flex System Chassis Management Module CMM CLI as described in the switch s User s Guide or CLI Referenc...

Page 36: ...the switch Use the management module interface to configure the IP addresses of the management module external interface eth0 and the switch so that they are both on the same subnet as the file server...

Page 37: ...ication Rel date 01 18 2013 Version 7 7 1 12 Status Inactive Acquiring feature licenses The base option for IBM Flex System Fabric EN4093 and EN4093R switches support twenty four total data ports four...

Page 38: ...lp for the Features on Demand feature activation process v Provide feedback to IBM about the Features on Demand process Note Your IBM ID and password are required to log into the Features on Demand we...

Page 39: ...ror applies to one port and the switch is operational You can continue to operate the switch however you must replace it as soon as possible When critical errors occur the switch does not operate To v...

Page 40: ...Diagnostic indicator in hex Failing functional area Failure criticality B0 FE Reserved Noncritical FF Switch good indicator Operation 30 EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...

Page 41: ...the terms of the warranty see the Warranty Information document Part CRU number Tier 1 IBM Flex System Fabric EN4093 10 Gb Scalable Switch 49Y4273 IBM Flex System Fabric EN4093R 10 Gb Scalable Switch...

Page 42: ...r 10 Gb SFP 49Y7886 3 m 40 Gb QSFP to four 10 Gb SFP 49Y7887 5 m 40 Gb QSFP to four 10 Gb SFP 49Y7888 10 m IBM MTP Fiber Optical 90Y3519 requires transceiver 49Y7884 30 m IBM MTP Fiber Optical 90Y3521...

Page 43: ...erproven compat us to make sure that the hardware and software is supported by your IBM product v Go to http www ibm com supportportal to check for information to help you solve the problem v Gather t...

Page 44: ...eCenter information is http www ibm com systems bladecenter The address for IBM IntelliStation information is http www ibm com systems intellistation How to send Dynamic System Analysis data to IBM Us...

Page 45: ...tp www ibm com partnerworld and click Find Business Partners on the right side of the page For IBM support telephone numbers see http www ibm com planetwide In the U S and Canada call 1 800 IBM SERV 1...

Page 46: ...36 EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...

Page 47: ...SS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include te...

Page 48: ...rive capacity or communications volume MB stands for 1 000 000 bytes and GB stands for 1 000 000 000 bytes Total user accessible capacity can vary depending on operating environments Maximum internal...

Page 49: ...evels of particulates or gases in your environment have caused damage to the switch module IBM may condition provision of repair or replacement of switch module or parts on implementation of appropria...

Page 50: ...he monitor Federal Communications Commission FCC statement Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules The...

Page 51: ...ause radio interference in which case the user may be required to take adequate measures Responsible manufacturer International Business Machines Corp New Orchard Road Armonk New York 10504 914 499 19...

Page 52: ...t in bereinstimmung mit dem Deutschen EMVG das EG Konformit tszeichen CE zu f hren Verantwortlich f r die Einhaltung der EMV Vorschriften ist der Hersteller International Business Machines Corp New Or...

Page 53: ...unications Commission KCC statement This is electromagnetic wave compatibility equipment for business Type A Sellers and users need to pay attention to it This is for any areas other than home Russia...

Page 54: ...44 EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...

Page 55: ...14 serial console cable 13 SFP module cable 13 Dynamic System Analysis 34 E electronic emission Class A notice 40 enabling management over external ports 8 enabling the external ports 8 error critical...

Page 56: ...module establishing a TCP IP session 20 N network requirements 3 8 noncritical errors 29 notes important 38 notices 37 electronic emission 40 FCC Class A 40 O obtaining the latest level of switch modu...

Page 57: ...operating speeds for internal and external ports 4 parts listing 31 removing or replacing 8 resetting and restarting 27 SSHv2 Telnet login 24 status 17 using browser based interface 23 switch module...

Page 58: ...48 EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...

Page 59: ......

Page 60: ...Part Number 47C9175 Printed in USA 1P P N 47C9175...

Reviews: