Table 4. Events for the Enclosure component (continued)
Event
Event Type
Severity
Message
Description
Cause
User Action
current_ok
STATE_CHANGE
INFO
currentSensor {0}
is ok.
The currentSensor
state is ok.
N/A
N/A
current_warn
STATE_CHANGE
WARNIN
G
currentSensor {0}
is degraded.
The currentSensor
state is degraded.
N/A
N/A
dcm_drawer_open
STATE_CHANGE
WARNIN
G
DCM {0} drawer is
open.
The DCM drawer is
open.
N/A
N/A
dcm_failed
STATE_CHANGE
WARNIN
G
DCM {0} is failed.
The DCM state is
failed.
N/A
N/A
dcm_not_available
STATE_CHANGE
WARNIN
G
DCM {0} is not
available.
The DCM is not
installed or not
responding.
N/A
N/A
dcm_ok
STATE_CHANGE
INFO
DCM {id[1]} is ok.
The DCM state is
ok.
N/A
N/A
drawer_failed
STATE_CHANGE
ERROR
drawer {0} is
failed.
The drawer state is
failed.
N/A
N/A
drawer_ok
STATE_CHANGE
INFO
drawer {0} is ok.
The drawer state is
ok.
N/A
N/A
drive_firmware_notavail
STATE_CHANGE
WARNIN
G
The firmware level
of drive {0} is not
available.
The firmware level
of the drive is not
available.
N/A
Check the installed
firmware level using
the
mmlsfirmware
command.
drive_firmware_ok
STATE_CHANGE
INFO
The firmware level
of drive {0} is
correct.
The firmware level
of the drive is
correct.
N/A
N/A
drive_firmware_wrong
STATE_CHANGE
WARNIN
G
The firmware level
of drive {0} is
wrong.
The firmware level
of the drive is
wrong.
N/A
Check the installed
firmware level using
the
mmlsfirmware
command.
enclosure_data
STATE_CHANGE
INFO
Enclosure data
found.
Successfully
queried the
enclosure details.
The
mmlsenclosure
all -L -Y
command reports
enclosure data.
N/A
enclosure_firmware_notavail
STATE_CHANGE
WARNIN
G
The firmware level
of enclosure {0} is
not available.
The firmware level
of the enclosure is
not available.
N/A
Check the installed
firmware level using
the
mmlsfirmware
command.
enclosure_firmware_ok
STATE_CHANGE
INFO
The firmware level
of enclosure {0} is
correct.
The firmware level
of the enclosure is
correct.
N/A
N/A
enclosure_firmware_unknown
STATE_CHANGE
WARNIN
G
The firmware level
of enclosure {0} is
unknown.
The SAS card is
unable to read
enclosure
firmware.
The SAS card does
not report the
enclosure
firmware.
Check the SAS
connectivity from
node to enclosure.
Use the
mmlsrecoverygrou
p rg_name -L --
pdisk
command to
verify if all the paths
to pdisk are
available. Check the
SAS connectivity
using a combination
of the
mmgetpdisktopolo
gy
and the
topsummary
command. If there is
an issue with the SAS
HBA or SAS Cable,
reboot the node to
see if this resolves
the issue. If not
contact your IBM
representative.
Chapter 1. Events 5
Summary of Contents for Elastic Storage System 3000
Page 1: ...IBM Elastic Storage System 3000 Version 6 0 1 Service Guide IBM SC28 3158 00...
Page 4: ...Index 63 iv...
Page 6: ...vi...
Page 8: ...viii...
Page 12: ...xii IBM Elastic Storage System 3000 Service Guide...
Page 30: ...18 IBM Elastic Storage System 3000 Service Guide...
Page 58: ...46 IBM Elastic Storage System 3000 Service Guide...
Page 64: ...52 IBM Elastic Storage System 3000 Service Guide...
Page 74: ...62 IBM Elastic Storage System 3000 Service Guide...
Page 76: ...64 IBM Elastic Storage System 3000 Service Guide...
Page 78: ...66 IBM Elastic Storage System 3000 Service Guide...
Page 79: ......
Page 80: ...IBM Product Number 5765 DME 5765 DAE SC28 3158 00...