Table 3. Events for the Canister component (continued)
Event
Event Type
Severity
Message
Description
Cause
User Action
bootdrive_mirror_failed
STATE_CHANG
E
ERROR
The bootdrive's
mirroring is failed.
The bootdrive's
mirroring is failed.
The
tsplatformstat
-a
command returns
a
FAILED
value for
at least one partition.
N/A
bootdrive_mirror_ok
STATE_CHANG
E
INFO
The bootdrive's
mirroring is OK.
The bootdrive's
mirroring is OK.
The
tsplatformstat
-a
command returns
optimal for all
partitions.
N/A
bootdrive_mirror
_unconfigured
STATE_CHANG
E
WARNING
The bootdrive's
mirroring is
unconfigured.
The bootdrive's
mirroring is
unconfigured.
The
tsplatformstat
-a
command returns
unconfigured for
mirroring.
N/A
bootdrive_missing
STATE_CHANG
E
ERROR
The bootdrive on
port {0} is missing or
dead.
One bootdrive is
missing or dead.
Redundancy is not
given anymore.
The
tsplatformstat
-a
command returns
only one instead of
two bootdrives. Two
drives are expected
to ensure
redundancy.
Inspect that the drive is
correctly installed on the
referenced port. Else
insert or replace the drive.
bootdrive_smart_failed
STATE_CHANG
E
ERROR
The smart
assessment of
bootdrive {0}
attached to port {1}
does not return OK.
The bootdrive's
smart assessment
does not return OK.
The
tsplatformstat
-a
command does
not return a
PASSED
value in the
selfAssessment
field for the
bootdrive.
Verify the smart status of
the bootdrive using
tsplatformstat
command or
smartctl
.
bootdrive_smart_ok
STATE_CHANG
E
INFO
The smart
assessment of
bootdrive {0}
attached to port {1}
returns OK.
The bootdrive's
smart assessment
returns OK.
The
tsplatformstat
-a
command returns
a
PASSED
in the
selfAssessment
field for the
bootdrive.
N/A
can_fan_failed
STATE_CHANG
E
WARNING
Fan {0} is failed.
The fan state is
failed.
The
mmlsenclosure
command reports
the fan as failed.
Check the fan status by
using the
mmlsenclosure
command. Replace the
fan module in the
canister.
can_fan_ok
STATE_CHANG
E
INFO
Fan {0} is OK.
The fan state is OK.
The
mmlsenclosure
command reports
the fan as working.
N/A
can_temp_bus_failed
STATE_CHANG
E
WARNING
Temperature sensor
{0} I2C bus is failed.
The temperature
sensor I2C bus
failed.
The
mmlsenclosure
command reports
the temperature
sensor with a failure.
Check the temperature
status by using the
mmlsenclosure
command.
can_temp_high_critical
STATE_CHANG
E
WARNING
Temperature sensor
{0} measured a high
temperature value.
The temperature
exceeded the actual
high critical
threshold value for at
least one sensor.
The
mmlsenclosure
command reports
the temperature
sensor with a failure.
Check the temperature
status by using the
mmlsenclosure
command.
can_temp_high_warn
STATE_CHANG
E
WARNING
Temperature sensor
{0} measured a high
temperature value.
The temperature
exceeded the actual
high warning
threshold value for at
least one sensor.
The
mmlsenclosure
command reports
the temperature
sensor with a failure.
Check the temperature
status by using the
mmlsenclosure
command.
can_temp_low_critical
STATE_CHANG
E
WARNING
Temperature sensor
{0} measured a low
temperature value.
The temperature has
fallen below the
actual low critical
threshold value for at
least one sensor.
The
mmlsenclosure
command reports
the temperature
sensor with a failure.
Check the temperature
status by using the
mmlsenclosure
command.
2 IBM Elastic Storage System 3000: Service Guide
Summary of Contents for Elastic Storage System 3000
Page 1: ...IBM Elastic Storage System 3000 Version 6 0 1 Service Guide IBM SC28 3158 00...
Page 4: ...Index 63 iv...
Page 6: ...vi...
Page 8: ...viii...
Page 12: ...xii IBM Elastic Storage System 3000 Service Guide...
Page 30: ...18 IBM Elastic Storage System 3000 Service Guide...
Page 58: ...46 IBM Elastic Storage System 3000 Service Guide...
Page 64: ...52 IBM Elastic Storage System 3000 Service Guide...
Page 74: ...62 IBM Elastic Storage System 3000 Service Guide...
Page 76: ...64 IBM Elastic Storage System 3000 Service Guide...
Page 78: ...66 IBM Elastic Storage System 3000 Service Guide...
Page 79: ......
Page 80: ...IBM Product Number 5765 DME 5765 DAE SC28 3158 00...