Table 3. Events for the Canister component (continued)
Event
Event Type
Severity
Message
Description
Cause
User Action
dimm_size_wrong
STATE_CHANG
E
ERROR
One or more
memory dimm
modules have an
unsupported
capacity.
The capacity of one
or more memory
dimm slots is not as
expected. This
configuration is not
supported.
The
/opt/ibm/gss
/tools/bin/
ess3kplt
command
returned some
capacity errors.
Inspect the output of the
ess3kplt
command to
see which memory dimm
slots have an
unsupported capacity and
replace those dimm
modules.
dimm_speed_ok
STATE_CHANG
E
INFO
All installed memory
dimms have the
expected speed.
The speed of all
populated memory
dimm slots is as
expected.
The
/opt/ibm/gss
/tools/bin/
ess3kplt
command
returned no speed
errors.
N/A
dimm_speed_wrong
STATE_CHANG
E
ERROR
One or more
memory dimm
modules have an
unsupported speed.
The speed of one or
more memory dimm
slots is not as
expected. This
configuration is not
supported.
The
/opt/ibm/gss
/tools/bin/
ess3kplt
command
returned some speed
errors.
Inspect the output of the
ess3kplt
command to
see which memory dimm
slots have an
unsupported speed and
replace those dimm
modules.
pair_canister_missing
STATE_CHANG
E
WARNING
Pair canister {0} is
missing or dead.
Could not get the
state of the pair
canister. It might be
missing or dead.
The
mmlsenclosure
command reports
only one canister
instead of two.
Check for detailed error
events of the referenced
canister node by using the
mmhealth
command.
Inspect the output of the
mmlsenclosure all -
L
command for the
referenced canister.
pair_canister_visible
STATE_CHANG
E
INFO
Pair canister {0} is
visible.
Successfully get the
state of the pair
canister.
The
mmlsenclosure
command reports
both canisters.
N/A
Enclosure events
The following table lists the events that are created for the Enclosure component.
Table 4. Events for the Enclosure component
Event
Event Type
Severity
Message
Description
Cause
User Action
adapter_bios_notavail
STATE_CHANGE
WARNIN
G
The bios level of
adapter {0} is not
available.
The bios level of
the adapter is not
available.
N/A
Check the installed
BIOS level using the
mmlsfirmware
command.
adapter_bios_ok
STATE_CHANGE
INFO
The BIOS level of
adapter {0} is
correct.
The BIOS level of
the adapter is
correct.
N/A
N/A
adapter_bios_wrong
STATE_CHANGE
WARNIN
G
The bios level of
adapter {0} is
wrong.
The bios level of
the adapter is
wrong.
N/A
Check the installed
BIOS level using the
mmlsfirmware
command.
adapter_firmware_notavail
STATE_CHANGE
WARNIN
G
The firmware level
of adapter {0} is
not available.
The firmware level
of the adapter is
not available.
N/A
Check the installed
BIOS level using the
mmlsfirmware
command.
adapter_firmware_ok
STATE_CHANGE
INFO
The firmware level
of adapter {0} is
correct.
The firmware level
of the adapter is
correct.
N/A
N/A
adapter_firmware_wrong
STATE_CHANGE
WARNIN
G
The firmware level
of adapter {0} is
wrong.
The firmware level
of the adapter is
wrong.
N/A
Check the installed
BIOS level using the
mmlsfirmware
command.
current_failed
STATE_CHANGE
ERROR
currentSensor {0}
failed.
The currentSensor
state is failed.
N/A
N/A
4 IBM Elastic Storage System 3000: Service Guide
Summary of Contents for Elastic Storage System 3000
Page 1: ...IBM Elastic Storage System 3000 Version 6 0 1 Service Guide IBM SC28 3158 00...
Page 4: ...Index 63 iv...
Page 6: ...vi...
Page 8: ...viii...
Page 12: ...xii IBM Elastic Storage System 3000 Service Guide...
Page 30: ...18 IBM Elastic Storage System 3000 Service Guide...
Page 58: ...46 IBM Elastic Storage System 3000 Service Guide...
Page 64: ...52 IBM Elastic Storage System 3000 Service Guide...
Page 74: ...62 IBM Elastic Storage System 3000 Service Guide...
Page 76: ...64 IBM Elastic Storage System 3000 Service Guide...
Page 78: ...66 IBM Elastic Storage System 3000 Service Guide...
Page 79: ......
Page 80: ...IBM Product Number 5765 DME 5765 DAE SC28 3158 00...