[TR1907] Transformer cannot gain access to database database_name with signon
information <user ID, password>
.
The database connection fails because quotes are added to the SQL query when the
data source is created in Framework Manager.
To successfully connect to the IQD data source and import the model, you must
first edit certain configuration files in the CS7Gateways\bin directory.
Procedure
1.
Open the cs7g.ini file and ensure the database type in the connection string is
CT, not CT15.
Cs7g.ini is located in the
installation_location
\CS7Gateways\bin directory.
2.
In the [Services] section, include the following:
CTDBA=ctdba, ctdba15
3.
Save your changes.
4.
Open the cogdmct.ini file and in the [UDA USER OPTIONS] section, specify
the following:
Attach=SET QUOTED_IDENTIFIER ON
Cogdmct.ini is located in the
installation_location
\CS7Gateways\bin directory.
5.
Save your changes.
6.
Open Transformer and import the data source.
Unable to Use an IQD Created in Framework Manager That
Contains an Oracle Stored Procedure
In Transformer, when trying to open an IQD created in Framework Manager that
contains an Oracle stored procedure, you may receive a message similar to the
following:
(TR0118) Transformer can't read the database [datasource] defined in <Lan
location>\<datasource><iqd_name>.iqd
.
DMS-E_General A general exception has occurred during operation 'execute'
The native SQL generated in an IQD created in Framework Manager is wrong. The IQD
cannot be used in Transformer.
To resolve this problem, execute the stored procedure in Framework Manager and
set the
Externalize Method
to
IQD
. Create a model query subject from the
executed stored procedure, then publish the package and open it in Transformer.
Preventing Errors When Model Calculations Use Double
Quotation Marks
If you try to open an .mdl-format model containing calculations that include
double quotation marks, as might be used to create concatenated categories, you
may get an error, even if you followed the recommended practice of wrapping
these calculations in single quotation marks.
This is because .mdl-format models do not support the use of single and double
quotation marks together, if the ObjectIDOutput flag is set to True, which is the
default model creation setting.
240
IBM Cognos Transformer Version 10.1.1: User Guide
Summary of Contents for Cognos
Page 1: ...IBM Cognos Transformer Version 10 1 1 User Guide ...
Page 106: ...92 IBM Cognos Transformer Version 10 1 1 User Guide ...
Page 136: ...122 IBM Cognos Transformer Version 10 1 1 User Guide ...
Page 160: ...146 IBM Cognos Transformer Version 10 1 1 User Guide ...
Page 174: ...160 IBM Cognos Transformer Version 10 1 1 User Guide ...
Page 326: ...312 IBM Cognos Transformer Version 10 1 1 User Guide ...
Page 352: ...338 IBM Cognos Transformer Version 10 1 1 User Guide ...
Page 394: ...380 IBM Cognos Transformer Version 10 1 1 User Guide ...
Page 398: ...384 IBM Cognos Transformer Version 10 1 1 User Guide ...
Page 411: ...Y year function 362 years between function 362 Index 397 ...