The
following
example
shows
a
vertical
orientation
for
installing
a
Fibre
Channel
switch
module
in
the
BladeCenter
unit.
Note:
For
information
about
installing
a
Fibre
Channel
switch
module
in
other
types
of
BladeCenter
units,
see
the
documentation
that
comes
with
the
BladeCenter
unit.
BladeCenter
unit
Latch
Release
lever
Fibre Channel
switch module
8.
Slide
the
switch
module
into
the
applicable
I/O-module
bay
until
it
stops.
9.
Push
the
release
lever
on
the
front
of
the
switch
module
to
the
closed
position.
After
you
insert
and
lock
the
switch
module,
it
is
turned
on,
and
a
POST
occurs
to
verify
that
the
switch
module
is
operating
correctly.
Notes:
a.
The
switch
module
takes
approximately
60
seconds
to
complete
the
POST.
When
the
switch
module
is
turned
on,
an
LED
test
occurs.
All
LEDs
are
lit
and
remain
lit
for
approximately
5
seconds;
then,
all
the
LEDs
except
the
OK
LED
turn
off.
The
power
LED
flashes
to
indicate
a
normal
POST
condition;
then,
POST
proceeds
as
described
in
the
next
step.
b.
To
maintain
proper
airflow,
make
sure
that
the
ventilation
areas
on
the
sides
of
the
switch
module
are
not
blocked.
10.
Make
sure
that
the
LEDs
on
the
switch
module
indicate
that
it
is
operating
correctly
(see
“Information
LEDs”
on
page
20).
v
When
the
POST
starts,
make
sure
that
the
green
power
LED
on
the
switch
module
is
flashing.
The
POST
tests
the
condition
of
firmware,
memory,
data
paths,
and
switch
logic
and
uses
the
fault
LED
to
indicate
pass
or
fail
conditions.
16
Brocade
4
Gb
SAN
Switch
Module:
Installation
Guide
Summary of Contents for BROCADE 4 GB FC HBAS
Page 1: ...Brocade 4 Gb SAN Switch Module for IBM Eserver BladeCenter Installation Guide ...
Page 2: ......
Page 3: ...Brocade 4 Gb SAN Switch Module for IBM Eserver BladeCenter Installation Guide ...
Page 12: ...x Brocade 4 Gb SAN Switch Module Installation Guide ...
Page 36: ...24 Brocade 4 Gb SAN Switch Module Installation Guide ...
Page 46: ...34 Brocade 4 Gb SAN Switch Module Installation Guide ...
Page 50: ...38 Brocade 4 Gb SAN Switch Module Installation Guide ...
Page 54: ...42 Brocade 4 Gb SAN Switch Module Installation Guide ...
Page 78: ...66 Brocade 4 Gb SAN Switch Module Installation Guide ...
Page 87: ......
Page 88: ... Part Number 24R9711 Printed in USA 1P P N 24R9711 ...