v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
7996,”
on
page
11
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Beep
code
Description
Action
1-2-3
DMA
page
register
write/read
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
1-2-4
RAM
refresh
verification
failed.
1.
Reseat
the
DIMMs
(see
“Removing
a
memory
module”
on
page
24
and
“Installing
a
memory
module”
on
page
24).
2.
Replace
the
lowest-numbered
pair
of
DIMMs;
then,
restart
the
workstation.
If
the
beep
code
error
remains,
go
to
3b.
Return
one
DIMM
at
a
time
from
the
failed
pair
to
its
connector,
restarting
the
server
after
each
DIMM,
to
identify
the
failed
DIMM.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
workstation
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
assembly
1-3-1
First
64K
RAM
test
failed.
1.
Reseat
the
DIMMs
(see
“Removing
a
memory
module”
on
page
24
and
“Installing
a
memory
module”
on
page
24).
2.
Replace
the
lowest-numbered
pair
of
DIMMs;
then,
restart
the
workstation.
If
the
beep
code
error
remains,
go
to
3b.
Return
one
DIMM
at
a
time
from
the
failed
pair
to
its
connector,
restarting
the
server
after
each
DIMM,
to
identify
the
failed
DIMM.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
workstation
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
assembly
2-1-1
Primary
DMA
register
test
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
2-1-2
Secondary
DMA
register
test
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
2-1-3
Primary
interrupt
mask
register
test
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
2-1-4
Secondary
interrupt
mask
register
test
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
2-3-4
Search
for
video
ROM
failed.
1.
Reseat
the
graphics
card.
2.
Replace
the
graphics
card.
Chapter
5.
Diagnostics
41
Summary of Contents for BladeCenter HC10 Type 7996
Page 1: ...BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Page 2: ......
Page 3: ...BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Page 8: ...vi BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Page 16: ...xiv BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Page 54: ...38 BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Page 112: ...96 BladeCenter HC10 Type 7996 Problem Determination and Service Guide ...
Page 113: ......
Page 114: ... Part Number 42C4881 Printed in USA 1P P N 42C4881 ...