Error
code
Description
Action
1762
Fixed
disk
configuration
error.
1.
Run
the
Configuration/Setup
Utility
program
and
load
the
defaults.
2.
Reseat
the
following
components:
a.
SAS
cables
b.
SAS
hard
disk
drive
c.
I/O
board
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
178x
Fixed
disk
error.
1.
Reseat
the
hard
disk
drive
cables.
2.
Replace
the
hard
disk
drive
cables.
3.
Run
the
hard
disk
drive
diagnostic
tests.
4.
Reseat
the
following
components:
a.
Optional
ServeRAID
™
-8i
adapter.
b.
Hard
disk
drive.
c.
I/O
board.
5.
Replace
the
components
listed
in
step
4
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
1800
Unavailable
PCI
hardware
interrupt.
1.
Run
the
Configuration/Setup
Utility
program
and
adjust
the
adapter
settings.
2.
Remove
each
adapter
one
at
a
time,
restarting
the
server
each
time,
until
the
problem
is
isolated.
1962
A
drive
does
not
contain
a
valid
boot
sector.
1.
Make
sure
that
a
bootable
operating
system
is
installed.
2.
Run
the
hard
disk
drive
diagnostic
tests.
3.
Reseat
the
following
components:
a.
SAS
drive
b.
SAS
hard
disk
drive
backplane
cable
c.
I/O
board
4.
Replace
the
components
listed
in
step
3
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Chapter
5.
Diagnostics
77
Summary of Contents for 88643RU - System x3850 - 8864
Page 1: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 28: ...12 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 38: ...22 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 176: ...160 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 190: ...174 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 191: ......
Page 192: ...Part Number 31R1885 Printed in USA 1P P N 31R1885...