v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8864,”
on
page
23
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
00180200
No
more
I/O
space
is
available
for
a
PCI
adapter.
1.
If
the
error
code
indicates
a
particular
PCI
slot
or
device,
remove
that
device.
2.
If
the
error
continues,
reseat
the
following
components:
a.
Each
adapter
b.
(Trained
service
technician
only)
PCI
board
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
00180300
No
more
memory
(above
1
MB
for
a
PCI
adapter).
1.
If
the
error
code
indicates
a
particular
PCI
slot
or
device,
remove
that
device.
2.
Reseat
the
following
components:
a.
Each
adapter
b.
(Trained
service
technician
only)
PCI
board
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
00180400
No
more
memory
(below
1
MB
for
a
PCI
adapter).
1.
Reseat
the
following
components:
a.
Each
adapter
b.
(Trained
service
technician
only)
PCI
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
00180500
PCI
option
ROM
checksum
error.
1.
Remove
the
failing
PCI
adapter.
2.
Reseat
the
following
components:
a.
Each
adapter
b.
(Trained
service
technician
only)
PCI
board
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
00180600
PCI
built-in
self-test
failure.
1.
If
the
error
code
indicates
a
particular
PCI
slot
or
device,
remove
that
device.
Note:
Slot
0
indicates
the
I/O
board.
2.
Reseat
the
following
components:
a.
Each
adapter
b.
(Trained
service
technician
only,
if
the
specified
board
is
a
FRU).
The
board
indicated
in
the
error
code.
(See
Chapter
3,
“Parts
listing,
Type
8864,”
on
page
23,
to
determine
CRU
or
FRU
status.)
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown
above,
restarting
the
server
each
time.
82
IBM
System
x3850
Type
8864:
Problem
Determination
and
Service
Guide
Summary of Contents for 88643RU - System x3850 - 8864
Page 1: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 28: ...12 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 38: ...22 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 176: ...160 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 190: ...174 IBM System x3850 Type 8864 Problem Determination and Service Guide...
Page 191: ......
Page 192: ...Part Number 31R1885 Printed in USA 1P P N 31R1885...