The following LEDs are on the operator information panel:
v
Hard disk drive activity LED:
When this LED is lit, it indicates that either of the
hard disk drives is in use.
v
System-locator LED:
Use this blue LED to visually locate the server if it is in a
location with numerous other servers. If your server supports IBM Director, you
can use IBM Director to light this LED remotely.
v
Information LED:
When this LED is lit, it indicates that a noncritical event has
occurred and is recorded in the error log. An LED near the failing component on
the system board is also lit to help isolate the error.
v
System-error LED:
When this LED is lit, it indicates that a system error has
occurred. A system-error LED is also on the rear of the server. An LED near the
failing component on the system board is also lit to help isolate the error.
USB connectors:
Connect USB devices to these connectors.
Notes:
1. If you want to attach a keyboard or mouse to this server, you must use a USB
keyboard or a USB mouse.
After installing a USB keyboard, you might need to use the Configuration/Setup
Utility program to enable keyboardless operation and prevent POST error
message 301 from being displayed during startup. For detailed information
about the USB keyboard and how to connect it to your server, see the
documentation that comes with the USB keyboard. For information about the
Configuration/Setup Utility program, see Chapter 2, “Configuring the server”, on
page 11.
2. You must use an external USB diskette drive if:
v
You want to attach a diskette drive to this server.
v
You need to create an update diskette that contains the latest baseboard
management controller firmware (see “Using the baseboard management
controller firmware update program” on page 20).
v
You need to create update diskettes that contain the latest server BIOS code
(see “Updating the BIOS code” on page 17).
Hard disk drive status LEDs:
On some server models, each hot-swap hard disk
drive has a status LED. If the status LED for a drive is lit continuously, that
individual drive is faulty. The interpretation of a flashing status LED depends on the
SCSI controller that is connected to the hot-swap drive, as follows:
v
When the drive is connected to the integrated SCSI controller with RAID
capabilities, a flashing status LED indicates that the drive is a secondary drive in
a mirrored pair and the drive is being synchronized.
v
When the drive is connected to an optional ServeRAID
™
controller, a slowly
flashing (one flash per second) status LED indicates that the drive is being
rebuilt. When the LED is flashing rapidly (three flashes per second), it indicates
that the controller is identifying the drive.
Chapter 1. Introducing the
Eserver
325 Type 8835 server
7
Summary of Contents for 8835 - Eserver 325 - 1 GB RAM
Page 1: ...IBM Eserver 325 Type 8835 User s Guide ERserver...
Page 2: ......
Page 3: ...IBM Eserver 325 Type 8835 User s Guide ERserver...
Page 6: ...Power cords 46 Index 49 iv IBM Eserver 325 Type 8835 User s Guide...
Page 14: ...xii IBM Eserver 325 Type 8835 User s Guide...
Page 54: ...40 IBM Eserver 325 Type 8835 User s Guide...
Page 66: ...52 IBM Eserver 325 Type 8835 User s Guide...
Page 67: ......
Page 68: ...Part Number 88P9312 Printed in U S A 1P P N 88P9312...