Installing
a
non-hot-swap
hard
disk
drive
in
bay
5,
6,
or
7
Bays
5,
6,
and
7
are
in
the
drive
cage.
The
drive
cage
is
located
just
above
the
front
adapter-support
bracket.
Note:
You
might
find
it
useful
to
work
with
the
server
laying
on
its
side.
Complete
the
following
steps
to
install
a
non-hot-swap
hard
disk
drive
in
bay
5,
6,
or
7:
1.
Review
the
safety
precautions
listed
in
“Safety
information”
on
page
119.
2.
Read
the
information
in
“Preinstallation
steps”
on
page
49.
3.
Turn
off
the
server
and
all
attached
devices.
Disconnect
all
external
cables
and
power
cords;
then
remove
the
side
cover.
See
“Removing
the
side
cover”
on
page
40
for
details.
4.
Remove
the
frame-support
bracket
and
disconnect
the
fan
cable
from
the
connector
on
the
system
board.
See
“Removing
the
frame-support
bracket”
on
page
41
for
details.
5.
If
your
server
has
hard
disk
drives
preinstalled
in
the
drive
cage,
disconnect
the
power
and
signal
cables
from
the
rear
of
the
drives.
6.
Rotate
the
drive
cage
out
of
the
server
until
it
locks
into
place
with
the
drive-cage-retention
tab.
The
open
ends
of
the
drive
slots
and
installed
drives
will
face
you.
Note:
Ensure
that
the
drive
cage
locks
into
place
over
the
drive-cage-retention
tab
by
pressing
the
drive
cage
all
the
way
up.
7.
Attach
the
guide
rails
to
the
side
of
the
drive
using
the
screws
provided.
If
you
obtained
your
optional
drive
from
IBM,
the
guide
rails
are
blue
plastic.
8.
Slide
the
drive
into
the
drive
cage
until
the
plastic
tabs
on
the
drive
guide
rails
lock
into
place
in
the
drive
cage.
Clear
any
cables
that
might
impede
the
replacement
of
the
drive
cage.
9.
Press
in
on
the
drive-cage-retention
tab,
and
rotate
the
cage
back
into
the
server.
Chapter
4.
Installing
options
53
Summary of Contents for 8480 - Eserver xSeries 205
Page 1: ...IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ERserver ...
Page 2: ......
Page 3: ...IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ERserver ...
Page 6: ...iv IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 10: ...viii IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 18: ...8 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 30: ...20 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 76: ...66 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 94: ...84 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 120: ...110 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 126: ...116 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 139: ...Appendix B Related service information 129 ...
Page 140: ...130 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 141: ...Appendix B Related service information 131 ...
Page 142: ...132 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 143: ...Appendix B Related service information 133 ...
Page 144: ...134 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 145: ...Appendix B Related service information 135 ...
Page 155: ...Appendix B Related service information 145 ...
Page 156: ...146 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 157: ...Appendix B Related service information 147 ...
Page 158: ...148 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 159: ...Appendix B Related service information 149 ...
Page 160: ...150 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 164: ...154 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 172: ...162 IBM xSeries 205 Type 8480 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 173: ......