2.
Click
Express
configuration
.
3.
Click
Next.
4.
In
the
“Configuration
summary”
window,
review
the
information.
To
change
the
configuration,
click
Modify
arrays
.
5.
Click
Apply
;
when
you
are
asked
whether
you
want
to
apply
the
new
configuration,
click
Yes
.
The
configuration
is
saved
in
the
controller
and
in
the
physical
drives.
6.
Exit
from
ServeRAID
Manager
and
remove
the
CD
from
the
CD-RW/DVD
drive.
7.
Restart
the
server.
Using
custom
configuration:
To
use
custom
configuration,
complete
the
following
steps:
1.
In
the
ServeRAID
Manager
tree,
click
the
controller.
2.
Click
Custom
configuration
.
3.
Click
Next
.
4.
In
the
“Create
arrays”
window,
from
the
list
of
ready
drives,
select
the
drives
that
you
want
to
group
into
the
array.
5.
Click
the
(Add
selected
drives)
icon
to
add
the
drives
to
the
array.
6.
If
you
want
to
configure
a
hot-spare
drive,
complete
the
following
steps:
a.
Click
the
Spares
tab.
b.
Select
the
physical
drive
that
you
want
to
designate
as
the
hot-spare
drive,
and
click
the
(Add
selected
drives)
icon.
7.
Click
Next
.
8.
Review
the
information
in
the
“Configuration
summary”
window.
To
change
the
configuration,
click
Back
.
9.
Click
Apply
;
when
you
are
asked
whether
you
want
to
apply
the
new
configuration,
click
Yes
.
The
configuration
is
saved
in
the
controller
and
in
the
physical
drives.
10.
Exit
from
ServeRAID
Manager
and
remove
the
CD
from
the
CD-RW/DVD
drive.
11.
Restart
the
server.
Viewing
the
configuration
You
can
use
ServeRAID
Manager
to
view
information
about
RAID
controllers
and
the
RAID
subsystem
(such
as
arrays,
logical
drives,
hot-spare
drives,
and
physical
drives).
When
you
click
an
object
in
the
ServeRAID
Manager
tree,
information
about
that
object
appears
in
the
right
pane.
To
display
a
list
of
available
actions
for
an
object,
click
the
object
and
click
Actions
.
Configuring
simple-swap
SATA
RAID
Important:
HostRAID
is
not
supported
on
the
SCO
6.0
and
UnixWare
7.14
operating
systems.
Use
the
Adaptec
HostRAID
Configuration
Utility
program
to
add
RAID
level-0
and
level-1
functionality
to
the
integrated
Serial
ATA
controller
(simple-swap
SATA
models).
Be
sure
to
use
this
program
as
described
in
this
document.
Use
this
program
to
perform
the
following
tasks:
v
Configure
a
redundant
array
of
independent
disks
(RAID)
array
v
View
or
change
the
RAID
configuration
and
associated
devices
Chapter
3.
Configuring
the
server
73
Summary of Contents for 79788BU
Page 1: ...IBM System x3550 Type 7978 User s Guide...
Page 2: ......
Page 3: ...IBM System x3550 Type 7978 User s Guide...
Page 30: ...16 IBM System x3550 Type 7978 User s Guide...
Page 62: ...48 IBM System x3550 Type 7978 User s Guide...
Page 100: ...86 IBM System x3550 Type 7978 User s Guide...
Page 101: ......
Page 102: ...Part Number 42C4977 Printed in USA 1P P N 42C4977...