Manager
to
configure
the
SCSI
controller.
Additional
information
abut
ServeRAID
Manager
is
also
available
from
the
Help
menu.
For
information
about
a
specific
object
in
the
ServeRAID
Manager
tree,
select
the
object
and
click
Actions
→
Hints
and
tips
.
Configuring
the
controller
By
running
ServeRAID
Manager
in
Startable
CD
mode,
you
can
configure
the
controller
before
you
install
the
operating
system.
The
information
in
this
section
assumes
that
you
are
running
ServeRAID
Manager
in
Startable
CD
mode.
To
run
the
ServeRAID
Manager
program
in
Startable-CD
mode,
turn
on
the
computer;
then,
insert
the
IBM
ServeRAID
Support
CD
into
the
CD-ROM
drive.
If
the
ServeRAID
Manager
program
detects
an
unconfigured
controller
and
ready
drives,
the
program
automatically
starts
the
Configuration
wizard.
In
the
Configuration
wizard,
you
can
select
express
configuration
or
custom
configuration.
Express
configuration
automatically
configures
the
controller
by
grouping
the
first
two
physical
drives
in
the
ServeRAID
Manager
tree
into
an
array
and
creating
a
RAID
level-1
logical
drive.
If
you
select
custom
configuration,
you
can
select
the
two
physical
drives
that
you
want
to
group
into
an
array
and
create
a
hot-spare
drive.
Using
express
configuration
To
use
the
express
configuration,
complete
the
following
steps:
1.
In
the
ServeRAID
Manager
tree,
click
the
controller
that
you
want
to
configure.
2.
From
the
toolbar,
click
Create
.
3.
Click
Express
configuration
.
4.
Click
Next
.
The
“Configuration
summary”
window
opens.
5.
Review
the
information
that
is
displayed
in
the
“Configuration
summary”
window.
To
change
the
configuration,
click
Modify
arrays
or
Modify
logical
drives
.
Note:
Some
operating
systems
have
size
limitations
for
logical
drives.
Before
you
save
the
configuration,
verify
that
the
size
of
the
logical
drive
is
appropriate
for
the
operating
system.
6.
Click
Apply
.
Click
Yes
when
asked
if
you
want
to
apply
the
new
configuration.
The
configuration
is
saved
in
the
controller
and
in
the
physical
drives.
7.
Exit
from
the
ServeRAID
Manager
program
and
remove
the
CD
from
the
CD-ROM
drive.
8.
Restart
the
computer.
Using
the
custom
configuration
To
use
the
custom
configuration,
complete
the
following
steps:
1.
In
the
ServeRAID
Manager
tree,
click
the
controller
that
you
want
to
configure.
2.
From
the
toolbar,
click
Create
.
3.
Click
Custom
configuration
.
4.
Click
Next
.
The
“Create
arrays”
window
opens.
5.
Click
the
applicable
tab
in
the
right
pane,
and
from
the
list
of
ready
drives,
select
the
two
drives
you
want
to
move
to
the
array.
6.
Click
the
icon
to
add
the
drives
to
the
array.
7.
If
you
want
to
configure
a
hot-spare,
complete
the
following
steps:
a.
Click
the
Spares
tab.
22
IBM
IntelliStation
M
Pro
Type
6218:
Installation
Guide
Summary of Contents for 621858U - IntelliStation M - Pro 6218
Page 3: ...IBM IntelliStation M Pro Type 6218 Installation Guide ...
Page 12: ...x IBM IntelliStation M Pro Type 6218 Installation Guide ...
Page 22: ...10 IBM IntelliStation M Pro Type 6218 Installation Guide ...
Page 26: ...14 IBM IntelliStation M Pro Type 6218 Installation Guide ...
Page 36: ...24 IBM IntelliStation M Pro Type 6218 Installation Guide ...
Page 77: ......
Page 78: ... Part Number 31R1996 Printed in USA 1P P N 31R1996 ...