4. After the update file has been written to the /tmp/fwupdate directory, enter the
following commands:
cd /usr/lpp/diagnostics/bin
./update_flash -f /tmp/fwupdate/RRyymmdd.img
Attention:
Do not overlook the periods (.) in the commands shown above. AIX
commands are case-sensitive. Type them exactly as shown.
You will be asked for confirmation to proceed with the firmware update and the required
reboot. If you confirm, the system will apply the new firmware, reboot, and return to the
AIX prompt. This may take up to ten minutes depending on the configuration of the
system.
Attention:
On some systems, the message
Wait for rebooting before stopping
may display on the system console. Do not turn off the system until the system has fully
rebooted to the AIX login prompt. If a shutdown is necessary at that time, log in as root
user and issue the shutdown command.
While the update is in progress, you will see
Rebooting...
on the display for several
minutes.
The firmware update is complete.
Updating System Firmware From the Service Processor Menus
This procedure requires a diskette drive to be installed in the system. This procedure
also requires a set of firmware update diskettes in backup format.
The service processor menus are available while the system is powered off. As a
privileged user, from the service processor main menu, select Service Processor
Setup, then select Reprogram Flash EPROM Menu. The update process requests
update diskettes as needed.
Updating System Firmware from the AIX Service Aids
Note: This service aid is supported only in online diagnostics.
Refer to the detailed instructions that are provided on the Web site with the latest
image.
Updating System Firmware from the AIX Command Line
Refer to the detailed instructions that are provided on the Web site with the latest
image.
Note: The update process can take up to sixty minutes, and the system reboots itself
during the update process.
Chapter 3. Using the Service Processor
63
Summary of Contents for 6.00E+04
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 User s Guide SA38 0606 00 ERserver IBM...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 User s Guide SA38 0606 00 ERserver IBM...
Page 14: ...xii pSeries 630 Model 6C4 and Model 6E4 User s Guide...
Page 16: ...xiv pSeries 630 Model 6C4 and Model 6E4 User s Guide...
Page 44: ...26 pSeries 630 Model 6C4 and Model 6E4 User s Guide...
Page 92: ...74 pSeries 630 Model 6C4 and Model 6E4 User s Guide...
Page 108: ...90 pSeries 630 Model 6C4 and Model 6E4 User s Guide...
Page 122: ...104 pSeries 630 Model 6C4 and Model 6E4 User s Guide...
Page 168: ...150 pSeries 630 Model 6C4 and Model 6E4 User s Guide...
Page 174: ...156 pSeries 630 Model 6C4 and Model 6E4 User s Guide...
Page 190: ...172 pSeries 630 Model 6C4 and Model 6E4 User s Guide...
Page 200: ...182 pSeries 630 Model 6C4 and Model 6E4 User s Guide...
Page 224: ...206 pSeries 630 Model 6C4 and Model 6E4 User s Guide...
Page 231: ......
Page 232: ...IBMR Printed in U S A August 2002 SA38 0606 00...