Configuring
the
baseboard
management
controller
LAN
connection
To
configure
the
baseboard
management
controller
local
area
network
(LAN)
connection
options
for
the
server,
use
the
LAN
configuration
utility
(lancfg.exe).
This
utility
is
on
the
baseboard
management
controller
firmware
update
diskette.
You
can
start
the
LAN
configuration
utility
after
you
update
the
baseboard
management
controller
firmware.
See
“Using
the
baseboard
management
controller
firmware
update
program”
on
page
14
for
instructions
for
downloading
and
updating
the
baseboard
management
controller
firmware.
To
configure
the
baseboard
management
controller
LAN
connection
by
using
the
LAN
configuration
utility,
complete
the
following
steps.
Note:
You
must
run
the
LAN
configuration
utility
(lancfg.exe)
in
a
DOS
command-line
session
after
you
start
the
server
from
the
startable
baseboard
management
controller
firmware
update
diskette.
Do
not
run
the
utility
from
a
DOS
window.
1.
After
the
baseboard
management
controller
firmware
update
is
completed,
a
command
prompt
is
displayed.
Type
lancfg
and
press
Enter.
The
LAN
configuration
utility
starts,
and
the
BMC
Information
screen
is
displayed.
The
default
values
that
are
displayed
are
read-only.
You
cannot
make
changes
in
this
screen.
To
use
the
LAN
configuration
utility,
press
F10
and
use
the
arrow
keys
to
select
the
menu
items
at
the
top
of
the
window.
2.
Select
LanCfg
.
The
LAN
Configuration
screen
is
displayed.
Type
the
values
for
the
baseboard
management
controller
in
the
fields
and
select
OK
.
Note:
The
Host
MAC
Address
field
is
read-only
and
cannot
be
changed
from
the
LAN
configuration
utility.
3.
Select
Alert
.
The
Alert
Setting
screen
is
displayed.
Type
the
applicable
values
for
the
server
in
the
fields
and
select
OK
.
Note:
In
the
IP
Address
field,
type
the
IP
address
of
the
workstation
to
which
the
baseboard
management
controller
will
forward
alerts.
4.
Select
Security
.
The
Security
Setting
screen
is
displayed.
You
can
maintain
the
four
baseboard
management
controller
user
accounts
on
this
screen.
To
make
changes
on
this
screen,
select
Edit
,
type
your
changes
in
the
Edit
screen,
and
select
OK
.
5.
After
you
make
all
the
changes
and
before
you
exit
the
LAN
configuration
utility,
remove
the
firmware
update
diskette
from
the
diskette
drive.
6.
Select
Exit
.
When
you
are
prompted
to
restart
the
server,
select
Reboot
.
Chapter
2.
Configuration
15
Summary of Contents for 326m - eServer - 7969
Page 1: ...326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 2: ......
Page 3: ...326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 6: ...iv 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 10: ...viii 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 20: ...10 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 26: ...16 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 66: ...56 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 114: ...104 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 129: ...Appendix B Related service information 119 ...
Page 130: ...120 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 131: ...Appendix B Related service information 121 ...
Page 132: ...122 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 133: ...Appendix B Related service information 123 ...
Page 134: ...124 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 135: ...Appendix B Related service information 125 ...
Page 148: ...138 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 149: ...Appendix B Related service information 139 ...
Page 150: ...140 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 151: ...Appendix B Related service information 141 ...
Page 152: ...142 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 153: ...Appendix B Related service information 143 ...
Page 158: ...148 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 164: ...154 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 169: ...W Web site IBM server products 1 IBM support 24 27 45 Index 159 ...
Page 170: ...160 326m Type 7969 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 171: ......
Page 172: ... Part Number 39Y5092 Printed in USA 1P P N 39Y5092 ...