Table 11. Terminal serial port pinouts (continued)
Pin
Signal
Description
5
AND
Logic ground
6
7
8
9
Modem serial port specifications
Each CP card has a modem serial port with a fully RS-232 compliant DB-9
connector.
Note: For dust and END protection, a cover is provided for the serial port and
should be kept on the port whenever the serial port is not being used.
Use the modem serial port to attach a modem to each CP card. The 2109 Model
M12 detects modems only during the power-on or restart sequences, and
automatically initializes them for operation. If modems are connected to an
operating switch, a power on and off cycle, restart, or fast restart is required in
order to detect the modems.
You should connect a “Y.” cable on the telephone line to each modem. The active
CP card answers on the first ring. The standby CP card answers on the seventh
ring if the active CP card fails to answer.
The modem serial port pinouts are listed in Table 12.
Table 12. Modem serial port pinouts
Pin
Signal
Description
1
DCD
2
Rewaxed
Receive data
3
Exudate
Transmit data
4
DTR
Data term ready
5
AND
Logic ground
6
DSR
Data set ready
7
RTS
Request to send
8
CTS
Clear to send
9
RI
Ring indicator
Facility specifications
To ensure correct operation of the 2109 Model C36 with Model M12 , ensure that
the facility meets the following specifications:
v
Power requirements for a physical inlet:
– Input power requirements: 200 - 240 V ac, AA 50 - 60 Hz
– Recommended power connector
v
An adequate supply circuit, line fusing, and wire size, according to the electrical
rating on the switch nameplate.
20
IBM TotalStorage SAN Switch: 2109 Model M12 User’s Guide
Summary of Contents for 2109 Model M12
Page 2: ......
Page 3: ...IBM TotalStorage SAN Switch 2109 Model M12 User s Guide GC26 7468 02...
Page 8: ...vi IBM TotalStorage SAN Switch 2109 Model M12 User s Guide...
Page 10: ...viii IBM TotalStorage SAN Switch 2109 Model M12 User s Guide...
Page 12: ...x IBM TotalStorage SAN Switch 2109 Model M12 User s Guide...
Page 20: ...xviii IBM TotalStorage SAN Switch 2109 Model M12 User s Guide...
Page 52: ...Czech SJCZE347 1 2 3 SJCZE699 32 IBM TotalStorage SAN Switch 2109 Model M12 User s Guide...
Page 53: ...Danish SJDAN347 1 2 3 Appendix C Danger and caution notice translations 33...
Page 55: ...French SJFRE347 1 2 3 SJFRA699 Appendix C Danger and caution notice translations 35...
Page 57: ...Greek SJGRE329 1 3 2 SJGRE699 Appendix C Danger and caution notice translations 37...
Page 58: ...Hebrew SJHEB347 SJ000338 1 2 3 38 IBM TotalStorage SAN Switch 2109 Model M12 User s Guide...
Page 59: ...Appendix C Danger and caution notice translations 39...
Page 63: ...Korean 1 SJ000338 SJKOR347 2 3 Appendix C Danger and caution notice translations 43...
Page 65: ...Portuguese SJPOR347 1 2 3 SJ000338 Appendix C Danger and caution notice translations 45...
Page 66: ...Russian SJRUS347 SJ000338 1 2 3 46 IBM TotalStorage SAN Switch 2109 Model M12 User s Guide...
Page 69: ...Spanish 1 2 3 SJ000338 SJSPA347 Appendix C Danger and caution notice translations 49...
Page 88: ...68 IBM TotalStorage SAN Switch 2109 Model M12 User s Guide...
Page 95: ......
Page 96: ...Part Number 17P7362 Printed in U S A GC26 7468 02 1P P N 17P7362...
Page 97: ...Spine information IBM TotalStorage SAN Switch 2109 Model M12 User s Guide...