Figure 82. Rack space requirements for the 5U expansion enclosure models
The following table shows the rack space requirements for the control enclosure in tabular form.
Table 23. Rack space requirements for the or control enclosure
Minimum rail length
Maximum rail depth
685 mm (27 in.)
765 mm (30.1 in.)
Additional space requirements
Ensure that these additional space requirements, as shown in Table 24 on page 88, are available around
the enclosures.
Table 24. Clearances
Location
Additional space requirements
Reason
Left and right sides
50 mm (2 in.)
Cooling air flow
Back
Minimum: 100 mm (4 in.)
Cable exit
Supported drives
Table 25 on page 88 provides drive specifications for your system.
Acoustical specifications for NVMe drives for each FlashSystem 5100 enclosure
The noise emission level that is stated is the declared (upper limit) sound power level, in decibels, for a
random sample of machines. All measurements are made in accordance with ISO 7779 and reported in
conformance with ISO 9296.
Acoustical Declaration with Noise Hazard Notice
Figure 83 on page 88 indicates the declared noise emissions values in accordance with ISO 9296.
Figure 83. Acoustical Declaration with Noise Hazard Notice
88 FlashSystem 5100 : Quick Installation Guide for MTM 2078-4F4, 2078-4H4, 2078-12G, 2078-AFG,
2078-24G, 2078-A9G, 2078-92G, and 2078-UHB